Electronic Components Datasheet Search
  English  ▼

X  

422ELC Datasheet(PDF) 2 Page - Protek Devices

Part # 422ELC
Description  DIGITAL PROCESS DATA LINE PROTECTOR
PDF  3 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PROTEC [Protek Devices]
Direct Link  http://www.protekdevices.com
Logo PROTEC - Protek Devices

422ELC Datasheet(HTML) 2 Page - Protek Devices

  422ELC Datasheet HTML 1Page - Protek Devices 422ELC Datasheet HTML 2Page - Protek Devices 422ELC Datasheet HTML 3Page - Protek Devices  
Zoom Inzoom in Zoom Outzoom out
 2 / 3 page
background image
2
www.protekdevices.com
05038.R3 11/03
422ELC
DEVICE CHARACTERISTICS
INSTALLATION INSTRUCTIONS
There are five (5) terminals on the LINE SIDE and five (5) terminals on
the EQUIPMENT SIDE of the 422ELC, 4 data lines and one ground.
Both grounds are connected together internally. A single low impedance
ground is sufficient. Incoming data lines are cut or disconnected from
the equipment to insert the 422ELC product. The incoming lines are to
be connected to the line side terminals as the equipment side lines are
connected to the equipment side terminals. The location of the product
should be as close to the equipment as possible. The 422ELC series is
designed with a short circuit failure mode to give maximum protection. A
fuse, fussable link, or circuit breaker is recommended for each data/
signal line on the input side for those that require an open circuit failure
mode.
Caution: A low DC resistance ground may not be a good ground.
Lightning contains a broad spectrum of frequencies up to 1 MHz. A low
impedance path to ground at the transient frequencies is necessary. A
ground strap is recommended or a #6 AWG stranded wire. For wire
lengths over 1.5 meters, there may be some excessive line to earth
potential under severe thunderstorm conditions.
30.0
MAXIMUM
CLAMPING
VOLTAGE
Line - Line
500A, 8/20µs
V
C
±VOLTS
MAXIMUM
CAPACITANCE
@ 0V, 1 MHz
C
pF
MAXIMUM
LINE THRUPUT
RESISTANCE
R
OHMS
12
30.0
125
MAXIMUM RATINGS @ 250C
MAXIMUM
CLAMPING
VOLTAGE
Line - Ground
500A, 8/20µs
V
C
±VOLTS
MAXIMUM
LEAKAGE
CURRENT
@ 12 V
OP
I
D
µA
ELECTRICAL CHARACTERISTICS @ 250C Ambient Temperature
Peak Operating Line Voltage (V
OP)
Operating Line Current (I
O)
Maximum Transient Voltage
Maximum Transient Current
(8/20µs waveform)
Operating & Storage Temperature
Response Time
±12V
200mA
20kV
10kA/Wire
40kA/Protector
-55°C to 100°C
< 1 nanosecond



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com