2 / 2 page ![]() PTC THERMISTORS: YS4019, YS4020,YSM4021 OVER-CURRENT PROTECTION DATA: SWITCHING TIMES: Thermistor connected to a 1000V r.m.s. supply via a series resistance, adjusted to set the initial cur- rent. Switching time defined as the time required for the current to reach 1/3 of the initial current at an ambient temperature of 25°C. CURRENT-VOLTAGE CHARACTERISTICS: YS4019 YS4020 & YSM4021 INSTRUMENT PROTECTION The input circuitry of digital multimeters and other instrumentation requires over- current protection against the unintentional fault conditions which can occur. PTC thermistors offer reliable, convenient and cost-effective protection. Solid state construction allows resettable operation, eliminating the inconvenience of fuse replacement. Modern multimeters, with wide-ranging functions, are particularly at risk. The inad- vertent application of a voltage source to an instrument in resistance mode will cause excessive currents within the input circuitry. Multi-channel instruments, such as oscillo- scopes, are also susceptible if the ground terminals are raised to high potential. These high currents, if unchecked, would destroy the input circuitry. The PTC thermistor is connected directly in series with the input terminals. It is chosen so that over the expected range of working conditions (current, voltage, ambient temperature) the device remains in a low resistance state, offering as little series resistance as possible to ensure accurate measurement. When a fault condition occurs, the abnormally high current causes sufficient I2R heating in the thermistor to switch it from low to high resistance, reducing the circuit current and preventing damage. After removal of the fault condition, the thermistor reverts to low resistance to re- establish normal operation. Devices can be chosen to achieve automatic reset (fault condition must be removed) or manual reset (power source disconnected). Initial current mA 50 100 200 500 1000 2500 30 4.2 0.70 0.21 0.1 25 4.0 1.0 0.16 0.05 Maximum trip time (secs) YS4019 YS4020 & YSM4021 Crown Industrial Estate, Priorswood Road 808 US Highway 1 967 Windfall Road Taunton, Somerset TA2 8QY UK Edison, New Jersey 08817-4695 USA St Marys, Pennsylvania 15857-3397 USA Tel +44 (0) 1823 335200 Tel +1 (732) 287 2870 Tel +1 (814) 834 9140 Fax +44 (0) 1823 332637 Fax +1 (732) 287 8847 Fax +1 (814) 781 7969 g |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |