Back Button TMP114 Datasheet HTML 29Page - Texas Instruments TMP114 Datasheet HTML 30Page - Texas Instruments TMP114 Datasheet HTML 31Page - Texas Instruments TMP114 Datasheet HTML 32Page - Texas Instruments TMP114 Datasheet HTML 33Page - Texas Instruments TMP114 Datasheet HTML 34Page - Texas Instruments TMP114 Datasheet HTML 35Page - Texas Instruments TMP114 Datasheet HTML 36Page - Texas Instruments TMP114 Datasheet HTML 37Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 33 / 50 page
background image
Table 8-9. Configuration Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
8
Reset
R/W
0h
Software reset bit.
When set to 1 it triggers software reset with a duration of 1 ms.
This bit will always read back 0
7
AVG
R/W
0h
Averaging enable bit. Averaging will force every measurement
including one-shot measurements to be averaged with eight
conversions.
0h: Averaging is disabled
1h: Averaging is enabled
6
CRC_En
R/W
0h
CRC enable. Enables the CRC feature for the next transaction
after a stop command is received.
0h = CRC is disabled
1h = CRC is enabled
5
Reserved
R
0h
Reserved
4
OS
R/W
0h
One-shot conversion trigger. After completing the one-shot
conversion this bit is reset to 0h. Triggering a one-shot
conversion will place the TMP114 into shutdown mode.
0h = Default
1h = Trigger a one-shot conversion
3
Mode
R/W
0h
Conversion mode selection bit.
0h = Continuous conversion mode
1h = Shutdown mode
2:0
Conv_Period[2:0]
R/W
4h
Conversion period setting. This bit field changes the conversion
period of the TMP114. If the averaging time is longer than the
conversion period setting the minimum conversion time will be
the averaging time.
0h = 6.4 ms
1h = 31.25 ms / 32 Hz
2h = 62.5 ms / 16 Hz
3h = 125 ms / 8 Hz
4h = 250 ms / 4 Hz
5h = 500 ms / 2 Hz
6h = 1 s / 1 Hz
7h = 2 s / 0.5 Hz
www.ti.com
TMP114
SNIS214A – JUNE 2021 – REVISED SEPTEMBER 2021
Copyright © 2021 Texas Instruments Incorporated
Submit Document Feedback
33
Product Folder Links: TMP114



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com