Electronic Components Datasheet Search
  English  ▼

X  

TMP114B Datasheet(PDF) 26 Page - Texas Instruments

Part # TMP114B
Description  TMP114 Ultra-Thin, 1.2-V to 1.8-V Supply, High Accuracy Digital Temperature Sensor with I2C Interface
PDF  50 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

TMP114B Datasheet(HTML) 26 Page - Texas Instruments

Back Button TMP114B Datasheet HTML 22Page - Texas Instruments TMP114B Datasheet HTML 23Page - Texas Instruments TMP114B Datasheet HTML 24Page - Texas Instruments TMP114B Datasheet HTML 25Page - Texas Instruments TMP114B Datasheet HTML 26Page - Texas Instruments TMP114B Datasheet HTML 27Page - Texas Instruments TMP114B Datasheet HTML 28Page - Texas Instruments TMP114B Datasheet HTML 29Page - Texas Instruments TMP114B Datasheet HTML 30Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 50 page
background image
8.5.4.3.1 CRC Enabled Reads
The TMP114 supports the ability to check data integrity with an 8-bit CRC value for every read transaction.
By setting the CRC_Enable bit to 1b in the Configuration Register, the device will use CRC to validate any
read transactions. During a CRC enabled read, the TMP114 will check the Target Address and Control Register
against the CRC value sent by the controller. The second CRC byte, after the restart, will be sent by the TMP114
and will check the Target Address, MSB, and LSB from the first register. All subsequent MSB and LSB bytes of
data sent from the TMP114 will have their own CRC values. Figure 8-17shows an overview of a read transaction
with CRC.
If the TMP114 determines the CRC failed, it will NACK on the CRC byte and the CRC_Flag bit in the Alert status
register will be set. The TMP114 will NACK after the restart to its target address and send FFh if the controller
continues clocking the SCL line until a STOP condition is sent and a new transaction started.
Target controls SDA line
Controller controls SDA line
I2C Bus
Target
Address
Control
Register
MSB from
Register
LSB from
Register
CRC
MSB from
Register
LSB from
Register
CRC
First CRC determined by Target Address and Control Register
Second CRC byte determined by preceding Target Address, MSB, and LSB bytes.
Sr
Re-START
Target
Address
CRC
Remaining CRC bytes determined by preceding MSB, and LSB bytes.
Figure 8-17. CRC Enabled Read
TMP114
SNIS214A – JUNE 2021 – REVISED SEPTEMBER 2021
www.ti.com
26
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: TMP114



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com