| Electronic Components Datasheet Search |
|
ESRF-HF Datasheet(PDF) 4 Page - ES Systems |
|
|
|||||||||||||||||||||||||||||
ESRF-HF Datasheet(HTML) 4 Page - ES Systems |
|
4 / 9 page ![]() Datasheet ESRF-HF 4/9 4. Flow Sensor Specifications Characteristic Absolute Unit Min. Typ. Max. Flow direction Unidirectional - Full scale ranges 100, 150, 250, 300, 500, 600, 700, 800, 1000, 1200, 1500 ln/min1 Flow cut2 1.0 %FS3 Max measured flow - - 1500 ln/min Calibration gas Clean, Dry Air4 - Operating temp. range5 -40[-40] - +85[+185] o C[oF] Compensated temp range6 0[+32] - +50[+122] o C[oF] Operating pressure 1.0 - 10 bara Proof pressure - - 11 bara Effective resolution 12 - - bits Response time - 100 - msec Total error band7 (<10%FS) - ±0.5 - %FS Total error band (>10%FS) - ±5.0+0.5 - %RD8 +%FS Accuracy9 (<10%FS) - ±0.5 - %FS Accuracy (>10%FS) - ±2.0+0.3 - %RD+%FS Orientation sensitivity10 - 0.001 - %FS/o Long term stability11 - - ±0.1 %FSS12 1 In normal liters per minute at 0oC and 1013 mbar 2 Flow measured below this point will always indicate 0 ln/min 3 % of the full scale 4 Other, non-aggressive, gases available upon request 5 The temperature range over which the sensor will produce an output proportional to flow (Non condensing humidity) 6 The temperature range over which the sensor will produce an output proportional to flow within the specified performance limits. Note that for valid datasheet values, ambient and gas temperatures must be the same 7 The maximum deviation from ideal transfer function over the entire compensated temperature and flow range. Includes all errors due to offset, full scale span, accuracy, thermal effect on offset, thermal effect on span and thermal hysteresis 8 % of the reading value 9 The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the flow range at 21oC [69.8oF]. Includes all errors due to flow non-linearity, flow hysteresis, non-repeatability and noise 10 Added measurement error due to orientation deviation from the optimal (calibration) position 11 Accelerated Life Test Profile: 100hours at 90oC 12 Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Umax) and the minimum (Umin) limits of the flow range |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |