Back Button LTC1871 Datasheet HTML 18Page - Analog Devices LTC1871 Datasheet HTML 19Page - Analog Devices LTC1871 Datasheet HTML 20Page - Analog Devices LTC1871 Datasheet HTML 21Page - Analog Devices LTC1871 Datasheet HTML 22Page - Analog Devices LTC1871 Datasheet HTML 23Page - Analog Devices LTC1871 Datasheet HTML 24Page - Analog Devices LTC1871 Datasheet HTML 25Page - Analog Devices LTC1871 Datasheet HTML 26Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 38 page
background image
LTC7840
22
Rev 0
For more information www.analog.com
The LTC7840 is a dual-phase constant frequency current
mode nonsynchronous step-up controller. This topology
makes the output voltage not limited by the IC voltage.
The LTC7840 can be configured in many ways as:
• a dual-phase dual-output boost converter with each
phase operating independently;
• a dual-phase dual-output boost converter with one
phase’s output connected to the other phase’s input.
As a result of this two-step-up configuration, a much
higher output voltage can be obtained;
• a dual-phase single-output boost converter;
• SEPIC topology;
• Other applications.
A wide 5.5V to 60V input voltage range can accommo-
date high input voltage surges. With the selectable lead-
ing edge blanking time, the noise on the SENSE pins at
the leading edge of the power MOSFET turn-on is filtered
out maximally. The programmable maximum duty cycle
provides the flexibility to the user for configuring different
topologies with LTC7840. The maximum current limit can
be adjusted by the user based on the sense resistor value.
For light load application, once ITH drops below 0.5V,
the controller is forced to skip cycles to maintain output
regulation. Each channel of the LTC7840 has a power
good indicator output to reflect if this channel’s output
voltage is within the regulation window. The LTC7840 can
be configured for single-phase, dual-phase and 4-phase
operation. The SYNC pin allows the IC to be synchro-
nized to an external clock. Without the external clock, the
switching frequency of the controller can be set by the
voltage on the FREQ pin. The LTC7840 provides overcur-
rent protection by the hiccup mode. The controller also
has output overvoltage protection.
In general, the external component selection is driven by
the characteristics of the load and the input supply. Next,
power MOSFETs are selected. Finally, input and output
capacitors are selected.
APPLICATIONS INFORMATION
Duty Cycle Considerations
For a boost converter operating in a continuous conduc-
tion mode (CCM), the duty cycle of the main switch is:
D
=
VO + VF – VIN
VO + VF
⎛
⎝⎜
⎞
⎠⎟
= tON • f
where VF is the forward voltage of the boost diode. The
minimum on-time for a given application operating in
CCM is:
tON(MIN) =
1
f
VO + VF – VIN(MAX)
VO + VF
⎛
⎝⎜
⎞
⎠⎟
For a given input voltage range and output voltage, it is
important to know how close the minimum on-time of the
application comes to the minimum on-time of the control
IC. The LTC7840 minimum on-time can be programmed
from 120ns to 200ns using the BLANK pin.
Minimum On-Time Limitations
In a boost converter, two steady-state conditions can
result in operation at the minimum on-time of the con-
troller. The first condition is when the input voltage is
close to the output voltage. When VIN approaches VOUT
the voltage across the inductor approaches zero during
the switch off-time. Under this operating condition the
converter can become unstable and the output can experi-
ence high ripple voltage oscillation at audible frequencies.
For applications where the input voltage can approach
or exceed the output voltage, consider using a SEPIC or
buck-boost topology instead of a boost converter.
The second condition that can result in operation at the
minimum on-time of the controller is at light load, in deep
discontinuous mode. As the load current is decreased, the
on-time of the switch decreases, until the minimum on-
time limit of the controller is reached. Any further decrease
in the output current will result in pulse-skipping, a typi-
cally benign condition where cycles are skipped in order
to maintain output regulation.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com