| Electronic Components Datasheet Search |
|
MAX7356 Datasheet(PDF) 13 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX7356 Datasheet(HTML) 13 Page - Maxim Integrated Products |
|
13 / 22 page ![]() 1-to-8 I2C Bus Switches/Multiplexers with Bus Lock-Up Detection, Isolation, and Notification ______________________________________________________________________________________ 13 Only the switch control register can be accessed through an I2C write or read command. All data bytes are for the switch control register. The last data byte in an I2C write command is retained by the switch control register. Register Access Protocol (MAX7357/MAX7358) Only the MAX7357 or MAX7358 I2C device address is required to gain access to its registers. A typical I2C command to communicate with the MAX7357 or MAX7358 starts with its device address and is followed directly by data bytes. Internal register addresses are not used in an I2C write or read command. For enhanced mode, all registers are accessed in sequence starting with the switch control register and follows the order defined by internal register addresses as shown in Table 2. Internal register addresses are 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, and 0x06 for switch control, configuration, flush-out sequence, lock- up indication, first and second bytes of the traffic prior to lock-up, and preconnection fault registers, respec- tively. When writing data to the register(s), addressing starts with address 0x00 and goes one higher in each subsequent byte and comes back to 0x00 again after 0x02 since the next four higher addressed registers are read only. Read access also starts with the internal reg- ister address 0x00 and goes one higher in each subse- quent byte and comes back to 0x00 again after 0x06. For basic mode, only the switch control register can be accessed through an I2C write or read command. All data bytes are for the switch control register. The last data byte in an I2C write command is retained by the switch control register. Incomplete bytes are ignored. Switch Control Register The switch control register (Figure 8) selects which channels will be connected to the main I2C bus. This register can be written and read through the main I2C bus. The POR value for the switch control register is 0x00—all switches disconnected. A SC_/SD_ downstream pair, or channel, is selected by the contents of the switch control register. All bits of the control byte are used to determine which channel is to B6 B0 B7 B5 B4 B3 B2 B1 CHANNEL SELECTION BITS (READ/WRITE) CHANNEL 0 CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 CHANNEL 5 CHANNEL 6 CHANNEL 7 Figure 8. Switch Control Register B7 B6 B5 B4 B3 B2 B1 B0 COMMAND X X X XXXX 0 Channel 0 disabled X X X XXXX 1 Channel 0 enabled X X X X X X 0 X Channel 1 disabled X X X X X X 1 X Channel 1 enabled X X X X X 0 X X Channel 2 disabled X X X X X 1 X X Channel 2 enabled X X X X 0 X X X Channel 3 disabled X X X X 1 X X X Channel 3 enabled X X X 0 X X X X Channel 4 disabled X X X 1 X X X X Channel 4 enabled X X 0 XXXX X Channel 5 disabled X X 1 XXXX X Channel 5 enabled X 0 X XXXX X Channel 6 disabled X 1 X XXXX X Channel 6 enabled 0 X X XXXX X Channel 7 disabled 1 X X XXXX X Channel 7 enabled Table 4. Switch Control Register Channel Selection X = Don’t care. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |