2 / 3 page ![]() TECHNICAL DATA SHEET CAR70M DS_CAR70M_G Subject to technical changes without notice * Released document – Copy is not subject to revision service! 2 / 3 Specification Input Voltage range 10.00 – 32.00VDC Stand-by current Typical 37.00mA @ 10.00V input Typical 29.00mA @ 32.00V input Input fuse 10.00A Protection Reverse polarity Over voltage protection (Transient suppression circuit) Output Voltage range 16.00 – 19.00V nominal Power 66.00W cont. 70.00W max. Initial set tolerance ±3% max. Load regulation -4% max. Line regulation ±1% max. Ripple & Noise < 120.00mVpk-pk Current limit Constant current Protection Short circuit, over temperature protection, over voltage protection Environmental Operation: Storage: Ambient Temperature -20°C to 40°C 40°C to 50°C, derating 35% -40°C to 75°C Pressure & Altitude 1200hPa to 570hPA max. 4600m above sea level 1200hPa to 115hPa max. 15000m above sea level Humidity (non-condensing) 5% to 95% r.H. 5% to 95% r.H. General Galvanic isolation Isolation voltage 2.00kV Input connector Cigarette lighter adapter Output connector Customer-specific Efficiency Typical 88% at 100% load MTBF > 100000h @ 25°C ambient temperature and GB per MIL HDBK217F Green procurement RoHS 2011/65/EU + 2015/863/EU REACH 1907/2006 WEEE 2012/19/EU Indicator Single green LED Ingress protection rating IEC60529, IP42 Cooling Convection cooled Safety & EMC Regulatory approvals Europe United Kingdom International USA/Canada CE UKCA CB Report IEC 60601-1 2nd edition CB Report IEC 60601-1 3rd edition UL60601-1 Electromagnetic Emissions Europe USA Medical electrical equipment EN 55011/55022 class B FCC15 class B IEC60601-1-2 Electromagnetic Immunity ESD immunity IEC61000-4-2, 8kV contact/ 15kV air Electromagnetic field immunity IEC61000-4-3, 80-2700MHz, 30V/m, modulation 80%/200Hz Electrical fast transient/burst immun- ity test IEC61000-4-4,+/-2kV, 5/50ns Surge immunity test Conducted Immunity IEC61000-4-5,+/-0,5kVsym, 1.2/50 (8/20)µs IEC61000-4-6, 0.15-80MHz, 10V, 80%, 1KHz, AM, with CDN ISO-Impulses Medical electrical equipment ISO7637-2, pulse 1 till 5, immunity test level III IEC60601-1-2 - other approvals on request |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |