Electronic Components Datasheet Search
  English  ▼

X  

0470182002 Datasheet(PDF) 3 Page - Molex Electronics Ltd.

Part # 0470182002
Description  SERIAL ATA BACKPLANE CONNECTOR 1.27mm PITCH
PDF  7 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MOLEX [Molex Electronics Ltd.]
Direct Link  http://www.molex.com
Logo MOLEX - Molex Electronics Ltd.

0470182002 Datasheet(HTML) 3 Page - Molex Electronics Ltd.

  0470182002 Datasheet HTML 1Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 2Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 3Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 4Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 5Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 6Page - Molex Electronics Ltd. 0470182002 Datasheet HTML 7Page - Molex Electronics Ltd.  
Zoom Inzoom in Zoom Outzoom out
 3 / 7 page
background image
PRODUCT SPECIFICATION
REVISION:
ECR/ECN INFORMATION:
TITLE:
SERIAL ATA BACKPLANE CONNECTOR
1.27mm PITCH
SHEET No.
H
EC No:
SH2016-0297
3 of 7
DATE:
2016/04/28
DOCUMENT NUMBER:
CREATED / REVISED BY:
CHECKED BY:
APPROVED BY:
PS-67492-001
Dixon Li
Anson Yin
Anson Yin
TEMPLATE FILENAME: PRODUCT_SPEC[SIZE_A](V.1). DOC
NOTES-
1. Time domain measurement equipment allows for delay adjustment of the pulses so launch
times can be synchronized. Frequency domain equipment will require the use of phase matched
fixturing .The fixturing skew should be verified to be <1 ps on a TDR.
2. The system rise time is to be set via equipment filtering techniques. The filter risetime is
significantly close to the stimulus risetime. Therefore the filter programmed equals the square root
of (tr(observed)) squared - (tr(stimulus)) squared. After filtering, verify the risetime is achieved using the
risetime reference traces on the PCB fixture.
3. Calibrate the system by substituting either precision 50-ohm loads or precision air lines (also
terminated in 50 ohm loads) for the test fixture. This places the calibration plane directly at the
input interface of the test fixture.
5.2 MECHANICAL REQUIREMENTS
DESCRIPTION
TEST CONDITION
REQUIREMENT
5.2.1
Visual and
dimensional
inspections
EIA 364-18
Visual, dimensional and functional per
applicable quality inspection plan.
Meet product drawing
requirements.
5.2.2
Insertion force
EIA 364-13
Measure the force necessary to mate the
connector assemblies at a max. rate of 12.5
mm(0.492") per minute.
20 N MAXIMUM
5.2.3
Removal force
EIA 364-13
Measure the force necessary to unmate the
connector assemblies at maximun rate of 12.5
mm(0.492") per miniute.
4 N MINMUN through 500
cycles
5.2.4
Durability
EIA 364-09
50 cycles for internal cabled application;
500 cycles for backplane/blindmate
application. Test done at a Maximum rate of
200 cycles per hour.
No physical damage. Meet
requirements of additional tests
as specified in the test
sequence



Html Pages

1 2 3 4 5 6 7


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com