| Electronic Components Datasheet Search |
|
LPT82 Datasheet(PDF) 1 Page - Astec America, Inc |
|
|
|||||||||||||||||||||||||||||
LPT82 Datasheet(HTML) 1 Page - Astec America, Inc |
|
1 / 2 page ![]() rev 5.3.04 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 1 Special Features Electrical Specs 80 Watts LPT80 Series • Power Factor Correction • EN61000-3-2 compliant • Universal input • 3” x 5” footprint • Remote sense on outputs 1 (& 2 for LPT81) • Power fail and remote inhibit • Wide range adjustable on outputs 1 (& 2 for LPT81) • Built-in Class B EMI filter • Overvoltage protection • Overload protection Operating temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient condition Input Input range 85-264 VAC 120-300 VDC Frequency 47-440 Hz Inrush current <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C Input current 1.5 A max. (RMS) @ 115 VAC Efficiency 75% typical at full load EMI filter FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Safety ground leakage current <1 mA @ 50/60 Hz, 264 VAC input Output Maximum power 60 W for convection( LPT81, 55 W); 85 W with 30 CFM forced air Adjustment range 3.3V - 5.5V on outputs one (and two 1.8 V - 3.5 V for LPT81) Hold-up time 20 ms @ 85 W load, 115 VAC nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 145% above peak rating Overvoltage protection Tracks outputs 1( & 2 for LPT81): 20% to 35% above output setting Logic Control Power Failure TTL Logic signal goes high 100-500 msec after main output; it goes low at least 4 ms before loss of regulation Remote inhibit Requires a contact closure to inhibit the outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. VDE 60950 UL 60950 CSA 60950 NEMKO 60950 AUSTEL 60950 CB Certificate & report CE Mark LVD Environmental Safety Total Power: 55-85 Watts Input Voltage: 85-264 VAC 120-370 VDC # of Outputs: Triple |
Similar Part No. - LPT82 |
|
Similar Description - LPT82 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |