| Electronic Components Datasheet Search |
|
HT36F2 Datasheet(PDF) 8 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT36F2 Datasheet(HTML) 8 Page - Holtek Semiconductor Inc |
|
8 / 36 page ![]() HT36F2 Rev. 1.00 8 August 15, 2005 All data memory areas can handle arithmetic, logic, in- crement, decrement and rotate operations directly. Ex- cept for some dedicated bits, each bit in the data memory can be set and reset by the ²SET [m].i² and ²CLR [m].i² instructions, respectively. They are also indi- rectly accessible through Memory pointer registers (MP0:01H, MP1:03H). Indirect Addressing Register Location 00H and 02H are indirect addressing registers that are not physically implemented. Any read/write op- eration of [00H] and [02H] access data memory pointed to by MP0 (01H) and MP1 (03H) respectively. Reading location 00H or 02H directly will return the result 00H. And writing directly results in no operation. The function of data movement between two indirect ad- dressing registers, is not supported. The memory pointer registers, MP0 and MP1, are 8-bit register which can be used to access the data memory by combining corresponding indirect addressing registers. Accumulator The accumulator closely relates to ALU operations. It is mapped to location 05H of the data memory and it can operate with immediate data. The data movement be- tween two data memory locations must pass through the accumulator. Arithmetic and Logic Unit - ALU This circuit performs 8-bit arithmetic and logic operation. The ALU provides the following functions: · Arithmetic operations (ADD, ADC, SUB, SBC, DAA) · Logic operations (AND, OR, XOR, CPL) · Rotation (RL, RR, RLC, RRC) · Increment & Decrement (INC, DEC) · Branch decision (SZ, SNZ, SIZ, SDZ ....) The ALU not only saves the results of a data operation but can also change the status register. Status Register - STATUS This 8-bit register (0AH) contains the zero flag (Z), carry flag (C), auxiliary carry flag (AC), overflow flag (OV), power down flag (PDF) and Watchdog time-out flag (TO). It also records the status information and controls the operation sequence. With the exception of the TO and PDF flags, bits in the status register can be altered by instructions like any other register. Any data written into the status register will not change the TO or PDF flags. In addition it should be noted that operations related to the status register may give different results from those intended. The TO and PDF flags can only be changed by system power up, Watchdog Timer overflow, executing the ²HALT² in- struction and clearing the Watchdog Timer. The Z, OV, AC and C flags generally reflect the status of the latest operations. In addition, on entering the interrupt sequence or exe- cuting a subroutine call, the status register will not be automatically pushed onto the stack. If the contents of status are important and the subroutine can corrupt the status register, the programmer must take precautions to save it properly. Interrupt The HT36F2 provides two internal timer counter inter- rupts on each bank. The Interrupt Control register (INTC;0BH) contains the interrupt control bits that sets the enable/disable and the interrupt request flags. Once an interrupt subroutine is serviced, all other inter- rupts will be blocked (by clearing the EMI bit). This scheme may prevent any further interrupt nesting. Other interrupt requests may occur during this interval but only the interrupt request flag is recorded. If a certain inter- rupt needs servicing within the service routine, the pro- grammer may set the EMI bit and the corresponding bit of the INTC to allow interrupt nesting. If the stack is full, the interrupt request will not be acknowledged, even if Bit No. Label Function 0C C is set if an operation results in a carry during an addition operation or if a borrow does not take place during a subtraction operation; otherwise C is cleared. Also it is affected by a ro- tate through carry instruction. 1AC AC is set if an operation results in a carry out of the low nibbles in addition or no borrow from the high nibble into the low nibble in subtraction; otherwise AC is cleared. 2 Z Z is set if the result of an arithmetic or logical operation is zero; otherwise Z is cleared. 3OV OV is set if an operation results in a carry into the highest-order bit but not a carry out of the highest-order bit, or vice versa; otherwise OV is cleared. 4 PDF PDF is cleared by either a system power-up or executing the ²CLR WDT² instruction. PDF is set by executing the ²HALT² instruction. 5TO TO is cleared by a system power-up or executing the ²CLR WDT² or ²HALT² instruction. TO is set by a WDT time-out. 6~7 ¾ Unused bit, read as ²0² Status (0AH) Register |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |