3 / 20 page ![]() Limit and Enclosed Switches Standards/How to read and understand the bar chart information A12 Honeywell Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada Standards IEC 947-1 explains the general rules relating to Low-voltage switchgear and controlgear. The purpose of this standard is to harmonize as much as possible the product performance and test requirements for equipment where the rated voltage does not ex- ceed 1,000 VAC or 1,500 VDC. IEC 947-5-1 is part 5 of the general rules which relates to Control- circuit devices and switching elements. Also within this part there is a section which considers Special Requirements For Control Switches With Positive Opening Operation. Any control switch which has this positive opening operation and conforms to these special requirements will be marked on the outside of the product with this symbol: The Contact Element Form defines the configuration of the contacts and the number of contacts within the switch. e.g. Form Za – both contact elements have the same polarity. Form Zb – the two contact elements are electrically separated. The Utilization Category defines the type of current carried (AC) Alternating current, (DC) Direct current and the typical application in which the switch is used e.g. AC15 – Control of Electromagnetic Loads (less than 72VA) DC13 – Control of electromagnets. The contact rating Designation relates to the utilization categories and defines the conventional thermal current lth (A), rated oper- ational current le (A) at rated operational voltages Ue and the VA rating e.g. A600 – The ‘‘A’’ denotes the maximum VA rating (AC) and the ‘‘600’’ denotes the maximum rated (AC) voltage. Q300 – The ‘‘Q’’ denotes the maximum VA rating (DC) and the ‘‘300’’ denotes the maximum rated (DC) voltage. These IEC standards have been adopted by CENELEC (The Eu- ropean Commitee for Electrotechnical Standardization) and have been identified by replacing IEC with EN 60 e.g. IEC 947-5-1 then becomes EN 60947-5-1. CENELEC has defined the dimensions and characteristics of two types of limit switch in the standards EN 50041 and EN 50047. These standards relate to Low voltage switchgear and control- gear for industrial use and define the enclosure dimensions, the operating point for various head actuators, the earth terminal re- quirement, the terminal marking and the minimum degree of IP protection. ELECTRICAL RATINGS IEC947-5-1 / EN60947-5-1 Designation & Rated operational current le (A) VA Utilization Category at rated operational voltage Ue rating 120V 240V 380V 480V 500V 600V Make Break AC15 A600 6 3 1.9 1.5 1.4 1.2 7200 720 AC15 A300 6 3 ———— 7200 720 AC15 B300 3 1.5 ———— 3600 360 AC14 D300 0.6 0.3 ———— 432 72 125V 250V DC13 Q300 0.55 0.27 69 69 DC13 R300 0.22 0.1 28 28 How to read and understand the bar chart information The following example relates to a unit which has a snap action basic and which has a roller pin plunger actuator i.e. GLCB01C. When reading these bar charts follow these rules: 1. Check what type of actuator was used to test the product, this is on the drawings which show the head style available. It will be one of two types: a) Vertical travel plunger b) Linear cam travel 2. Start reading from top left of figure B, at the arrow labeled ‘‘A’’. 3. Follow the black arrows and the black strip on the chart. The black strip indicates that there is a circuit between the termi- nals whose numbers are shown on the left and when white there is no circuit. All dimensions are in mm/(inches). Figure A Figure B Look at Figures A and B as examples. Actuator type used for test is the linear Cam travel type (b) shown left. The start point is at the arrow marked ‘‘A’’ (See fig. B). This shows the free position to be 5.3 mm from the vertical center line of the unit. At this stage there is a circuit between the terminals 21-22 but no circuit between terminals 13-14. The unit can be actuated until it reaches the operating posi- tion which is10.5 mm from the center line – a travel distance of10.5 – 5.3 = 5.2 mm from the free position. At this point the circuit arrange- ment changes – no circuit between 21-22 but making a circuit between 13-14. If, however, the contacts of terminals 21-22 weld together and will not separate, a mechanical safety feature will take effect if the switch is travelled past the point from which positive opening is assured, 13.9 mm. As the switch returns it reaches the release position at 8.9 mm from the center line. The circuit will change back to the original state and the difference between the operating position and the release position gives what is known as the differential travel i.e. 10.5 – 8.9 = 1.6 mm. The asterisk (*) indicates the point from which the positive opening is assured. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |