16 / 31 page ![]() TLE8458 Mode Control Data Sheet 16 Rev. 1.1, 2014-04-01 5.2.6 Power Up After a Power-up the device enters per default into Stand-By Mode. Above V S,PU the VCC output voltage follows the supply V S closely. In Stand-By Mode, the Power-up is indicated by a HIGH signal on the RxD pin and a LOW signal on the TxD pin. Figure 9 Power-up Level 5.2.7 Over-Temperature Protection The TLE8458 is protected against thermal over-heating. Over-heating could be caused by a short circuit on the V CC power supply or by a permanent short on the LIN bus combined with a high ambient temperature. In case of an over-temperature event, the TLE8458 eliminates the root cause of the over-temperature event. Two different temperature sensors are implemented inside the TLE8458. One temperature sensor protects the voltage regulator and controls the output voltage V CC, the second temperature sensor protects the LIN transmitter output stage. In case the junction temperature on the LIN output stage raises above the threshold T > T SD,LIN, the temperature sensor disables the LIN output stage. The TLE8458 is still able to receive data from the LIN bus. If the temperature falls below the threshold, T < T SD,LIN, the output stage will be enabled and the communication can start again. An integrated hysteresis on the temperature sensor avoids toggling during over-temperature events. An over- temperature event on the LIN bus will not cause any operation mode change. In case the junction temperature on the V CC power output stage raises above the threshold T > TSD,VCC, the temperature sensor shuts down the output voltage V CC. If the junction temperature falls below the threshold, T> T SD,VCC, the power supply VCC will be enabled again. An integrated hysteresis on the temperature sensor avoids toggling during over-temperature events. Stand-by Mode Power Down EN TxD RxD Power Down VS VCC VS,PU VRxD,H VCC VS VS,PU |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |