Back Button HV7151SP Datasheet HTML 51Page - Hynix Semiconductor HV7151SP Datasheet HTML 52Page - Hynix Semiconductor HV7151SP Datasheet HTML 53Page - Hynix Semiconductor HV7151SP Datasheet HTML 54Page - Hynix Semiconductor HV7151SP Datasheet HTML 55Page - Hynix Semiconductor HV7151SP Datasheet HTML 56Page - Hynix Semiconductor HV7151SP Datasheet HTML 57Page - Hynix Semiconductor HV7151SP Datasheet HTML 58Page - Hynix Semiconductor HV7151SP Datasheet HTML 59Page - Hynix Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 89 page
background image
HV7151SP
CMOS Image Sensor
Confidential
With Image Signal Processing
This document is a general product description and is subject to change without notice. Hynix
Semiconductor Inc. does not assume any responsibility for use of circuits described and no patent
licenses are implied.
- 55 -
2003 Hynix Semiconductor Inc.
Dark G Threshold [DPCGTH : 94h : 20h]
7
6
5
4
3
2
1
0
Dark G Threshold
0
0
1
0
0
0
0
0
The register value specify the current G pixel’s differential value with neighboring G pixels, and is used
to check whether current G pixel is dark bad pixel or not.
Dark R/B Threshold [DPCGTH : 95h : 20h]
7
6
5
4
3
2
1
0
Dark R/B Threshold
0
0
1
0
0
0
0
0
The register value specify the current R or B pixel’s differential value with neighboring G pixels, and is
used to check whether current R or B pixel is dark bad pixel or not.
Reference of Amp Gain for Dark Bad Pixel Concealment [DPCGAIN : 96h : 38h]
7
6
5
4
3
2
1
0
Reference of Amp Gain for Dark Bad Pixel Concealment
0
0
1
1
1
0
0
0
Amp Gain exceeds Reference of Amp Gain for Dark Bad Pixel Concealment, dark bad concealment
operation is performed when dark bad pixel concealment mode is “01
Contrast factor Y [CONTY : 97h : 80h]
7
6
5
4
3
2
1
0
Contrast factor Y
1
0
0
0
0
0
0
0
Contrast Adjustment is performed for multiplying Y data by Contrast Factor Y, respectively.
Programmable range of Contrast Factor Y is 0 ~ 2.
Cont Y = Y data * B<7:0>/128.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com