4 / 26 page ![]() Rev. K 06/20 4 InnoSwitch-CH www.power.com Over-Temperature Protection The thermal shutdown circuitry senses the primary die temperature. This threshold is set to 142 °C with 75 °C hysteresis. When the die temperature rises above this threshold the power MOSFET is disabled and remains disabled until the die temperature falls by 75 °C, at which point it is re-enabled. A large hysteresis of 75 °C is provided to prevent over-heating of the PC board due to continuous fault condition. Current Limit Operation The current limit circuit senses the current in the power MOSFET. When this current exceeds the internal threshold (I LIMIT), the power MOSFET is turned off for the remainder of that switch cycle. The current limit state-machine reduces the current limit threshold by discrete amounts under medium and light loads. The leading edge blanking circuit inhibits the current limit comparator for a short time (t LEB) after the power MOSFET is turned-on. This leading edge blanking time has been set so that current spikes caused by capacitance and secondary-side rectifier reverse recovery time will not cause premature termination of the switching pulse. Each switching cycle is terminated when the Drain current of the primary power MOSFET reaches the current limit of the device. Auto-Restart In the event of a fault condition such as output overload, output short-circuit or external component/pin fault, the InnoSwitch-CH enters into auto-restart (AR) operation. In auto-restart operation the power MOSFET switching is disabled for t AR(OFF). There are 2 ways to enter auto-restart after the secondary has taken control: 1. Continuous switching requests from the secondary for time period exceeding t AR. 2. No requests for switching cycles from the secondary for a time period exceeding t AR(SK). The first condition corresponds to a condition wherein the secondary controller makes continuous cycle requests without a skipped-cycle for more than t AR time period. The second method was included to ensure that if communication is lost, the primary tries to restart again. Although this should never be the case in normal operation, this can be useful in the case of system ESD events for example where a loss of communication due to noise disturbing the secondary controller, is resolved when the primary restarts after an auto-restart off time. The auto-restart alternately enables and disables the switching of the power MOSFET until the fault is removed. The auto-restart counter is gated by the switch oscillator in SOA mode the auto-restart off timer may appear to be longer. The auto-restart counter is reset once the primary PRIMARY BYPASS pin falls below the undervoltage threshold V BPP-VBPP(HYS). Safe-Operating-Area (SOA) Protection In the event there are two consecutive cycles where the primary power MOSFET switch current reaches current limit (I LIM) within the blanking (t LEB) and current limit (tILD) delay time, the controller will skip approximately 2.5 cycles or ~25 msec. This provides sufficient time for reset of the transformer without sacrificing start-up time into large capacitive load. Auto-restart timing is increased when the device is operating in SOA-mode. Primary-Secondary Handshake Protocol At start-up, the primary initially switches without any feedback information (this is very similar to the operation of a standard TOPSwitch™, TinySwitch™ or LinkSwitch™ controllers). If no feedback signals are received during the auto-restart on-time, the primary goes into auto-restart and repeats. However under normal conditions, the secondary chip will power-up through the FORWARD pin or directly from VOUT and then take over control. From then Figure 6. Primary – Secondary Handshake Flowchart. onwards the secondary is in control of demanding switching cycles when required. The handshake flowchart is shown in Figure 6. In the event the primary stops switching or does not respond to cycle requests from the secondary during normal operation when the secondary has control, the handshake protocol is imitated to ensure that the secondary is ready to assume control once the primary begins switching again. This protocol for an additional handshake is also invoked in the event the secondary detects that the primary is providing more cycles than were requested. The most likely event that could require an additional handshake is when the primary stops switching resulting from a momentary line drop-out or brown-out event. When the primary resumes operation, it will default into a start-up condition and attempt to detect hand- shake pulses from the secondary. Yes tAR(OFF) tAR Yes Yes No No No S: Has powered up within tAR P: Has Received Handshaking Pulses S: Has Taken Control? P: Switching S: Sends Handshaking Pulses P: Stops Switching, Hands Over Control to Secondary P: Not Switching S: Doesn’t Take Control P: Continuous Switching S: Doesn’t Take Control P: Goes to Auto-Restart Off S: Bypass Discharging P: Auto-Restart S: Powering Up P: Primary Chip S: Secondary Chip End of Handshaking, Secondary Control Mode PI-7416-110414 Start P: Powered Up, Switching S: Powering Up |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |