15 / 26 page ![]() Applications Information (Continued) and a high-side FET on-pulse is skipped, the LM3495 incre- ments a 4 bit counter. If 16 high-gate pulses are skipped consecutively while COMP/SD stays above 2V, the LM3495 will enter hiccup mode. The counter is reset when the COMP/SD pin goes below 2V. During soft-start the cycle skipping function of the low-side current limit is active, but the ability to enter hiccup mode is disabled. CURRENT LIMIT SENSE RESISTOR For applications that require a higher degree of accuracy for the low-side current limit, a dedicated current sense resistor can be added between ground and the source of the low- side FET. Figure 6 shows the circuit connection when using a dedicated current limit sensing resistor, R SNS. When using a dedicated current limit sensing resistor, the equation governing the low-side current limit becomes: MAXIMUM CURRENT SENSE In order to keep the low-side current sense amplifier within its linear range, the peak sense voltage, V SNS, between the CSL and SW/CSH pins should remain below 200 mV. V SNS =IPK x(RDSON-LO +RSNS) The value I PK can be determined by following the equations in the Output Inductor section of Design Considerations. HIGH-SIDE CURRENT LIMIT The LM3495 employs a second comparator that monitors the voltage across the high-side FET when it is on. This provides protection against a short circuit at the switch node, which the low-side current limit cannot detect. If the drain- to-source voltage of the high-side FET exceeds 500 mV while the FET is on, the LM3495 will immediately enter hiccup mode. A 200 ns blanking period after the high-side FET turns on is used to prevent switching transient voltages from tripping the high-side current limit without cause. HICCUP MODE During hiccup mode, the LM3495 disables both the high-side and low-side FETs and begins a cool down period of 4096 switching cycles. At the conclusion of this cool down period, the regulator performs an internal 400 cycle soft start iden- tical to the soft start at turn-on. During soft start only the high-side current limit can put the LM3495 into hiccup mode. low-side current cannot put the LM3495 into hiccup mode during soft start, although it can limit duty cycle. If a short at the output persists when soft start is done, the part will begin counting high-side pulses skipped due to the low-side cur- rent limit and will re-enter hiccup mode 16 cycles later. The long term effect observed will be 4096 cycles with the power FETs disabled, and then 416 (400 + 16) cycles where they are enabled. The hiccup protection mode is designed to protect the exter- nal components of the circuit (output inductor, FETs and input voltage source) from thermal stress. For example, assume that the low–side current limit is10A. Once in hiccup mode the effective duty cycle for the high-side FET and output inductor will be D*(416/4096). For the low-side FET it will be (1-D)(416/4096). This means that even under the worst case conditions (minimum switching frequency and maximum duty cycle, D MAX = 96%), the average current through the inductor and high-side FET will be 975 mA and the average current seen by the low-side FET will be 40 mA. PARALLEL LOW-SIDE SCHOTTKY DIODE Many synchronous buck regulators include a Schottky diode in parallel with the low-side power FET. The low forward drop and short reverse recovery time of Schottky diodes can improve efficiency by preventing the FET’s body diode from turning on. This technique is most effective in circuits with output currents of 5A or less. The parallel Schottky diode must be placed as close as possible to the power FET to prevent trace inductance from negating the gains in effi- ciency. ADAPTIVE DUTY CYCLE CLAMP The adaptive duty cycle clamp is an extra layer of protection used during high current conditions or large load transients. When a high-side pulse is skipped due to current limit, the output voltage tends to decrease rapidly. The steady state control loop of the LM3495 responds by commanding a higher duty cycle at the next high-side turn-on. The result is a combination of high voltage across the output inductor and long duty cycles that could result in inductor saturation. The adaptive duty cycle clamp prevents inductor saturation by providing a dynamic maximum duty cycle, D CLAMP. The clamp is based on the sensed input and output voltages. D CLAMP can be predicted with the following equation: D CLAMP cannot exceed 100% SHUTDOWN The LM3495 can be put into a low power shutdown mode by bringing the voltage at the COMP/SD pin below 0.3V. A signal-level BJT or FET can be controlled by most CMOS or TTL logic signals to perform this function. The collector-to- emitter or drain-to-source capacitance should be less than 20 pF to minimize the effect on the control loop compensa- 20169939 FIGURE 6. Current Limit Sense Resistor www.national.com 15 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |