| Electronic Components Datasheet Search |
|
UCS3205 Datasheet(PDF) 14 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS3205 Datasheet(HTML) 14 Page - Microchip Technology |
|
14 / 30 page ![]() UCS3205 DS20006433A-page 14 2020 Microchip Technology Inc. 4.0 FUNCTIONAL DESCRIPTION The UCS3205 is a single-channel load switch with highly integrated load protection for applications up to 22V. The device protects the power supply with its configurable current limit feature. The current limit threshold is set with an external resistor. The same pin can be connected to external measurement or detection circuitry, such as an ADC, comparator or MCU, eliminating the need for a shunt in the power path. The UCS3205 protects the load from being supplied by voltages higher than intended (overvoltage lockout). It also has a thermal shutdown circuit, which will shut the switch off when junction temperature exceeds the limit. The device implements Fast Role Swap (FRS) capability and reverse current blocking that can be disabled via the DIR pin, allowing it to work as a bidirectional switch depending on the application requirements. The device’s DIR pin is normally grounded for Fast Role Swap applications. The FRS pin is normally grounded for bidirectional current flow applications. This device can be programmed to either latch off or retry in the event of a Fault. 4.1 Mode Control Figure 4-1 shows the UCS3205 state diagram. 4.1.1 RESET MODE When the UCS3205 is in the Reset state, the device is in its lowest current consumption state. The port power switch is off. The FAULT# pin is not asserted. If the FAULT# pin is asserted prior to entering Reset state, it will be released. When in Reset mode, a low-to-high transition on the EN pin will start the transition of the UCS3205 to its next state. If there are no Faults detected and t > t STRT_CLD has elapsed, the UCS3205 will transition into the Operating state. If there is an Overvoltage, Back-Voltage, Short-Circuit, Overcurrent, or Thermal Shutdown Fault, the device will transition into the Fault state. 4.1.2 OPERATING MODE In order for the UCS3205 to enter Operating mode, VIN/VOUT must be above VIN_STRT/VOUT_STRT for tSTRT_EN, before the low-to-high transition on EN, before turning on the switch can take place. Once the switch is on, the VIN voltage can be decreased to 2.85V. Whenever the UCS3205 is in Operating mode, the port power switch will be on. In this case, the FAULT# pin is not asserted. If the FAULT# pin is asserted prior to entering Reset state, it will be released. The UCS3205 cannot be in the Operating state if any of the following conditions exist: • Overvoltage, Short-Circuit, Overcurrent, Thermal Shutdown or Back-Voltage Fault •VIN < VUV_HIGH •EN < VIH When in Operating mode, a high-to-low transition on the EN pin will make the UCS3205 transition into the Reset state. If any Fault conditions occur while in the Operating state, the UCS3205 will automatically transition into the Fault state. 4.1.3 FAULT MODE The UCS3205 automatically enters the Fault state from the Operating and Retry states when any of the following events are detected: • An Overvoltage (OV) condition on the VIN pin (see Section 4.4 “VIN Overvoltage Detection”). • A Short-Circuit (SC) condition (see Section 4.3 “Short-Circuit Detection”). • An Overcurrent (OC) condition (see Section 4.2 “Overcurrent Detection”). • Maximum allowable internal die temperature is exceeded – Thermal Shutdown (TSD) (see Section 4.8 “Thermal Shutdown”). • A Back-Voltage (BV) condition (see Section 4.7 “Back-Voltage Detection”). The UCS3205 enters the Fault state from the Reset state when there is a low-to-high transition on the EN pin and any of the following events are detected: • Maximum allowable internal die temperature is exceeded • Back-Voltage condition, • Short-Circuit condition on the VOUT pin • Overcurrent condition on the VOUT pin • Overvoltage condition on the VIN pin When the UCS3205 is in Fault mode, the port power switch will be off and the FAULT# pin is asserted. 4.1.4 RETRY MODE The only way for the UCS3205 to enter the Retry state is from the Fault state and the LATCH pin must be low. When the UCS3205 is in Retry mode, the port power switch will be on and the FAULT# pin is asserted (see Figure 4-5). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |