4 / 14 page ![]() Philips Semiconductors Objective specification AU5783 J1850/VPW transceiver with supply control function 1999 May 11 4 PINNING Pin configuration 1 2 3 4 14 13 12 SO14 11 AU5783 5 6 7 10 9 8 INH RX GND BUS LWAKE BAT TX NSTB GND R/F N.C. LOAD N.C. 4X/LOOP SL01225 Figure 2. Pin configuration Pin description SYMBOL PIN DESCRIPTION R/F 1 Rise/fall time control input; connect to ground potential via a resistor GND 2 Ground 4X/LOOP 3 Tx mode control input; low: normal mode; high: 4X mode; float: loopback NSTB 4 Network STandBy power control input; low: transmit function disabled (low power modes); high: transmit function enabled TX 5 Transmit data input; low: transmitter passive; high: transmitter active RX 6 Receive data output; low: active bus condition detected; high: otherwise N.C. 7 Not connected BAT 8 Battery supply input, 12V nominal LWAKE 9 Local wake-up input, edge sensitive INH 10 Activity indication flag (inhibit) output high side driver; e.g., to control a voltage regulator. Active high enables the regulator LOAD 11 Bus load in/output BUS 12 Bus line transmit/receive input/output, active high side driver N.C. 13 Not connected GND 14 Ground FUNCTIONAL DESCRIPTION The AU5783 is an integrated line transceiver IC that interfaces an SAE/J1850 protocol controller IC to the vehicle’s multiplex bus line. It is primarily intended for automotive “Class B” multiplexing applications in passenger cars using VPW (Variable Pulse Width) modulated signals with a nominal transmission speed of 10.4 kbit/s. The device provides transmit and receive capability as well as protection to a J1850 electronic module. A J1850 link controller feeds the transmit data stream to the transceiver’s TX input. The AU5783 transceiver waveshapes the TX data input signal so as to minimize electromagnetic emission. The bus output signal features controlled rise & fall characteristic including rounded shape. A resistance being connected to the R/F control input sets the bus output slew rate. The LOAD output is connected to the physical bus line via an external load resistor Rld. The load resistor pulls the bus line to ground potential being the default state e.g. when no transmitter outputs an active state. This output ensures the J1850 network will not be affected by a potential loss of ground condition at an individual electronic control unit. The AU5783 includes a bus receiver with filter function to minimize susceptibility against interference. The logic state of the J1850 bus signal is indicated at the RX output being connected to the J1850 link controller. The AU5783 also provides advanced low-power modes to help minimize ignition-off power consumption of an electronic control unit. The bus receiver function is kept alive in the low-power modes. If an active state is being detected on the bus line this will be indicated via the RX output. By default the AU5783 enters the low-power standby mode when the mode control inputs NSTB and 4X/LOOP are not driven. Ignition-off current draw can be reduced further by turning off the voltage regulator being typically provided in an electronic control unit. This is supported by the activity indication function of the AU5783. In this application the activity indication flag INH will control external devices such as a voltage regulator. To turn-off the INH flag and thus the voltage regulator, the go to sleep command needs to be applied to the Network Standby power control input, e.g., NSTB = 0. The INH output is turned off after the sleep time-out period thereby, reducing the power consumption of an electronic control unit to an extremely low level. The activity indication flag INH will be turned on again upon detection of a remote wake-up condition (i.e. bus activity) or upon detection of a local wake-up condition or a respective command from the microcontroller. A local wake-up condition is detected when an edge occurs at the wake-up input LWAKE. The INH flag will also be turned on upon detection of a high input level at the mode control input NSTB. Activation of the INH output enables external devices e.g., a voltage regulator. This condition will power-up logic devices e.g., a microcontroller in order to perform appropriate action, e.g., activation of the AU5783 and the J1850 network. The AU5783 provides a high-speed data transmission mode where the bus output waveshape function is disabled. In this mode transmit signals are output as fast as possible thus allowing higher data rates, e.g. the so-called 4X mode with 41.6 kbit/s nominal speed. The AU5783 also provides a loop-back mode for diagnostic purpose, e.g. self-test of an electronic control unit. In loop-back mode the bus transmit and receive functions are disabled thus |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |