| Electronic Components Datasheet Search |
|
RJP4013ASP Datasheet(PDF) 3 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
RJP4013ASP Datasheet(HTML) 3 Page - Renesas Technology Corp |
|
3 / 5 page ![]() RJP4013ASP Preliminary R07DS1008EJ0200 Rev.2.00 Page 3 of 4 Mar 27, 2013 Application Example CM + – 8 Xe Tube Trigger Transformer VCM 76 5 12 3 4 VCM ICP CM VGE 350 V 150 A 400 µF 4 V Maximum Operation Conditions IGBT driver Precautions on Usage 1. IGBT has MOS structure and its gate is insulated by thin silicon oxide. So please handle carefully to protect the device from electrostatic charge. 2. Gate drive voltage during on-period must be applied to satisfy the rating of maximum pulse collector current. And turn-off dv/dt must become less than 400 V/ s. 3. The operation life should be endured until repeated discharge of 5,000 times under the charge current (IXe 150 A : full luminescence condition) of main capacitor. Repetition period under full luminescence condition is over 3 seconds. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|