Electronic Components Datasheet Search
  English  ▼

X  

DAC39RFS10 Datasheet(PDF) 55 Page - Texas Instruments

Part # DAC39RFS10
Description  DAC39RF10 10.24-GSPS, 16-bit, Dual and Single Channel, Multi-Nyquist Digital-to-Analog Converter (DAC) with JESD204B, C Interface
PDF  178 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

DAC39RFS10 Datasheet(HTML) 55 Page - Texas Instruments

Back Button DAC39RFS10 Datasheet HTML 51Page - Texas Instruments DAC39RFS10 Datasheet HTML 52Page - Texas Instruments DAC39RFS10 Datasheet HTML 53Page - Texas Instruments DAC39RFS10 Datasheet HTML 54Page - Texas Instruments DAC39RFS10 Datasheet HTML 55Page - Texas Instruments DAC39RFS10 Datasheet HTML 56Page - Texas Instruments DAC39RFS10 Datasheet HTML 57Page - Texas Instruments DAC39RFS10 Datasheet HTML 58Page - Texas Instruments DAC39RFS10 Datasheet HTML 59Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 178 page
background image
in the SYSREF_POS field. Each bit of SYSREF_POS represents a potential SYSREF sampling position. If a
bit in SYSREF_POS is set to 1, then the corresponding SYSREF sampling position has a potential setup or
hold violation. Upon determining the valid SYSREF sampling positions (the positions of SYSREF_POS that are
set to 0) the desired sampling position can be chosen by setting SYSREF_SEL to the value corresponding to
that SYSREF_POS position. In general, the middle sampling position between two setup and hold instances
is chosen. Ideally, SYSREF_POS and SYSREF_SEL are performed at the nominal operating conditions of the
system (temperature and supply voltage) to provide maximum margin for operating condition variations. This
process can be performed at final test and the optimal SYSREF_SEL setting can be stored for use at every
system power up. Further, SYSREF_POS can be used to characterize the skew between CLK± and SYSREF±
over operating conditions for a system by sweeping the system temperature and supply voltages. For systems
that have large variations in CLK± to SYSREF± skew, this characterization can be used to track the optimal
SYSREF sampling position as system operating conditions change. In general, a single value can be found that
meets timing over all conditions for well-matched systems, such as those where CLK± and SYSREF± come from
a single clocking device.
The step size between each SYSREF_POS sampling position can be adjusted using SYSREF_ZOOM. When
SYSREF_ZOOM is set to 0, the delay steps are coarser. When SYSREF_ZOOM is set to 1, the delay steps
are finer. See the electrical specifications table for delay step sizes when SYSREF_ZOOM is enabled and
disabled. In general, SYSREF_ZOOM is recommended to always be used (SYSREF_ZOOM = 1) unless a
transition region (defined by 1's in SYSREF_POS) is not observed, which can be the case for low clock
rates. Bits 0 and 20 of SYSREF_POS are always be set to 1 because there is insufficient information to
determine if these settings are close to a timing violation, although the actual valid window can extend beyond
these sampling positions. The value programmed into SYSREF_SEL is the decimal number representing the
desired bit location in SYSREF_POS. Table 8-4 lists some example SYSREF_POS readings and the optimal
SYSREF_SEL settings. Although 20 sampling positions are provided by the SYSREF_POS status register,
SYSREF_SEL only allows selection of the first 16 sampling positions, corresponding to SYSREF_POS bits 0 to
15. The additional SYSREF_POS status bits are intended only to provide additional knowledge of the SYSREF
valid window. In general, lower values of SYSREF_SEL are selected because of delay variation over supply
voltage, however in the fourth example a value of 15 provides additional margin and can be selected instead.
Table 8-4. Examples of SYSREF_POS Readings and SYSREF_SEL Selections
SYSREF_POS[19:0]
OPTIMAL SYSREF_SEL
SETTING
0x092[3:0]
(Largest Delay)
0x091[7:0](1)
0x090[7:0](1)
(Smallest Delay)
b1000
b01100000
b00011001
8 or 9
b1000
b00000000
b00110001
12
b1000
b01100000
b00000001
6 or 7
b1000
b00000011
b00000001
4 or 14
b1100
b01100011
b00011001
6
(1)
Underlined 0 indicates the bits that are selected, as given in the last column of this table.
To use SYSREF Windowing:
1. Apply SYSREF and DEVCLK
2. Set SYSREF_RECV_SLEEP=0, SYSREF_POS_SEL=0, and SYSREF_ZOOM=1
3. Set SYSREF_PROC_EN=1
4. Read SYSREF_POS and determine proper setting for SYSREF_SEL. If proper sampling point cannot be
determined, set SYSREF_ZOOM=0 and retry.
8.3.6 Digital Signal Processing Blocks
The digital signal processing blocks are shown in Figure 8-13. The device includes four digital up-converter
(DUC) blocks supporting four complex (IQ) input streams that can be combined at different RF frequencies. The
four DUCs can be flexibly assigned and summed together for either DAC output in the channel bonder. The final
signal processing block is a extra interpolate by 2 filter for use with DES mode.
Table 8-5 and Table 8-6 list the available modes for single channel and dual channel outputs, respectively.
www.ti.com
DAC39RF10
SBASAC8 – MAY 2023
Copyright © 2023 Texas Instruments Incorporated
Submit Document Feedback
55
Product Folder Links: DAC39RF10



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com