| Electronic Components Datasheet Search |
|
ADIS16255PCBZ Datasheet(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADIS16255PCBZ Datasheet(HTML) 18 Page - Analog Devices |
|
18 / 20 page ![]() ADIS16255 Preliminary Technical Data Rev. PrA | Page 18 of 20 The ALM_CTRL register controls the source data selection, static/dynamic selection, filtering selection and digital I/O usage for the alarms. Rate of Change Calculation ) or ( MSB ALM_MAG1/2 to according M with Y Compare m ChangeAlar of Rate M with compared be to Factor Y ALM_MAG1/2 in comparison for Magnitude M Data Output Sampled y(n) 2 ALM_SMPL1/ in samples of Number N C C DS N 1 n C C C DS ? ) ( ) 1 ( 1 < > ⇒ − + = = = = = ∑ = n y n y N Y DS C Table 31. ALM_MAG1 Register Definition Address Default Format Access 0x21, 0x20 0x0000 N/A R/W The ALM_MAG1 register contains the threshold level for Alarm 1. The contents of this register are nonvolatile. Table 32. ALM_MAG1 Bit Designations Bit Description 15 Comparison polarity: 1 = greater than, 0 = less than 14 Not used 13:0 Data bits: format matches source data format Table 33. ALM_SMPL1 Register Definition Address Default Format Access 0x25, 0x24 0x0000 Binary R/W Table 34. ALM_SMPL1 Bit Designations Bit Description 15:8 Not used 7:0 Data bits Table 35. ALM_MAG2 Register Definition Address Default Format Access 0x23, 0x22 0x0000 N/A R/W Table 36. ALM_MAG2 Bit Designations Bit Description 15 Comparison polarity: 1 = greater than, 0 = less than 14 Not used 13:0 Data bits: format matches source data format Table 37. ALM_SMPL2 Register Definition Address Default Format Access 0x27, 0x26 0x0000 Binary R/W Table 38. ALM_SMPL2 Bit Designations Bit Description 15:8 Not used 7:0 Data bits Table 39. ALM_CTRL Register Definition Address Default Format Access 0x29, 0x28 0x0000 N/A R/W Table 40. ALM_CTRL Bit Designations Bit Value Description 15 Rate of change (ROC) enable for alarm 2 1 = rate of change, 0 = static level 14:12 Alarm 2 source selection 000 Disable 001 Power supply output 010 Gyroscope output 011 Inactive 100 Inactive 101 Auxiliary ADC output 110 Temperature sensor output 111 Inactive 11 Rate of change (ROC) enable for alarm 1 1 = rate of change, 0 = static level 10:8 Alarm 1 source selection 000 Disable 001 Power supply output 010 Gyroscope output 011 Inactive 100 Inactive 101 Auxiliary ADC output 110 Temperature sensor output 111 Inactive 7:5 Not used 4 Filtered data comparison 1 = filtered data, 0 = unfiltered data 3 Not used 2 Alarm output enable 1 = enabled, 0 = disabled 1 Alarm output polarity 1 = active high, 0 = active low 0 Alarm output line select 1 = DIO1, 0 = DIO0 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |