8 / 44 page ![]() NXP Semiconductors PCA9575 16-bit I2C-bus and SMBus, level translating, low voltage GPIO with reset and interrupt When bus-hold feature is not selected, the I/O ports can be configured to have pull-up or pull-down by programming the pull-up/pull-down configuration register. 7.2 Device address Following a START condition, the bus controller must send the address of the target it is accessing and the operation it wants to perform (read or write). Address configuration for the device depends on the package type chosen. The device offered in a 24-pin package has a fixed target address for the PCA9575 as shown in Figure 6. 002aad567 0 1 0 0 0 0 0 R/W fixed target address Figure 6. PCA9575 device address for 24-pin version The last bit of the first byte defines the operation to be performed. When set to logic 1 a read is selected, while logic 0 selects a write operation. The target address for the 28-pin version of the PCA9575 is shown in Figure 7. 002aad583 0 1 0 A3 A2 A1 A0 R/W fixed target address hardware selectable Figure 7. PCA9575 device address for 28-pin version 7.3 Command register Following the successful acknowledgement of the target address + R/W bit, the bus controller sends a byte to the PCA9575, which is stored in the Command register. 002aad568 AI 0 0 0 D3 D2 D1 D0 register address Auto-Increment flag Reset state = 00h Remark: The Command register does not apply to Software Reset I2C-bus address. Figure 8. Command register The lowest 4 bits are used as a pointer to determine which register is accessed. Only a Command register code with the 4 least significant bits equal to the 16 allowable values as defined in Table 4 is acknowledged. Reserved or undefined command codes are not acknowledged. At power-up, this register defaults to 00h, with the AI bit set to logic 0, and the lowest 4 bits set to logic 0. If the Auto-Increment flag is set (AI = 1), the 4 least significant bits of the Command register are automatically incremented after a read or write. This allows the user to program and/or read the 16 command registers (listed in Table 4) sequentially. It will then roll over to register 00h after the last register is accessed and the selected registers are overwritten or re-read. If the Auto-Increment flag is cleared (AI = 0), the 4 least significant bits are not incremented after data is read or written, only one register will be repeatedly read or written. PCA9575 All information provided in this document is subject to legal disclaimers. © 2023 NXP B.V. All rights reserved. Product data sheet Rev. 5.0 — 31 May 2023 8 / 44 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |