| Electronic Components Datasheet Search |
|
82V3002APVG Datasheet(PDF) 13 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
82V3002APVG Datasheet(HTML) 13 Page - Renesas Technology Corp |
|
13 / 30 page ![]() FUNCTIONAL DESCRIPTION 13 October 15, 2008 IDT82V3002A WAN PLL WITH DUAL REFERENCE INPUT Figure - 5 TIE Control Circuit Diagram The TIE Control Block will work under the control of the Step Generation circuit when it is enabled manually or automatically (by the TIE_en pin or TIE auto-enable logic generated by the State Control Circuit). The selected reference signal is compared with the feedback signal (current output feedback from the Frequency Select Circuit) by the Measure Circuit. The phase difference between the input reference and the feedback signal is sent to the Storage Circuit for TIE correction. The Trigger Circuit generates a virtual reference with the phase corrected to the same position as the previous reference according to the value stored in the Storage Circuit. With this TIE correction mechanism, the reference is switched without generating a step change in phase. Figure - 6 shows the phase transient that would result if a reference switch is performed with the TIE Control Block enabled. Figure - 6 Reference Switch with TIE Control Block Enabled The phase difference in the Storage Circuit can be cleared by applying a logic low pulse to the TCLR pin. The reset pulse should be at least 300 ns. When the IDT82V3002A primarily enters Holdover Mode for short time periods and then turns back to Normal Mode, the TIE Control Circuit should not be enabled. This will prevent undesired accumulated phase change between the input and output. If the TIE Control Block is disabled manually or automatically during the reference switching, the phase of the output signal will align with that of the new reference. The phase slope is limited to 5 ns per 125 µs. Figure - 7 shows the phase transient resulting from a reference switch with the TIE Control Block disabled. Step Generation TIE_en Select Circuit Fref0 Fref1 IN_sel Measure Circuit Storage Circuit Trigger Circuit Feedback signal TCLR Fref Virtual Reference Signal Input Clock Fref0 Time = 0.00 s Time = 0.25 s Time = 0.50 s Time = 0.75 s Time = 1.0 s Time = 1.25 s Time = 1.50 s Time = 1.75 s Output Clock Fref1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |