| Electronic Components Datasheet Search |
|
SDN-C Datasheet(PDF) 3 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SDN-C Datasheet(HTML) 3 Page - List of Unclassifed Manufacturers |
|
3 / 7 page ![]() Power Supplies 3 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 119 Description Catalog Number SDN 5-24-100C SDN 10-24-100C Input Nominal Voltage 115 - 230 Vac -AC Range 85 - 264 Vac -DC Range 1 90 - 375 Vdc -Frequency 43 - 67 Hz Nominal Current 2 1.65 - 0.55 A 3.2 - 1.0 A -Inrush current max. Typ. < 15 A Typ.< 30 A Efficiency (Losses 3) > 88% typ. (14 W) > 90% typ. (24 W) Power Factor Correction Active power factor correction to better than 0.92 Output Nominal Voltage 4 24 V (23.5~28.5 Vdc Adj.) -Tolerance < ±2 % overall (combination Line, load, time and temperature related changes) Initial Voltage Setting 24.5 V ± 1% -Ripple 5 < 50 mVpp PARD PARD (Periodic and Random Deviation) = 100 mV peak-peak max Overvoltage Protection > 30.5 but < 33 Vdc, auto recovery Power Back Immunity < 35 V Nominal Current 5 A (120 W) 10 A (240 W) -Peak Current 6 1.5 × Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc -Short Circuit Current 1.5 x Nominal Current at near zero volts at short circuit condition -Current Limit PowerBoost™ Parallel Operation Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting). Holdup Time >20 ms (Full load, 100 Vac Input @ T amb=+25°C) to 95% output voltage Voltage Fall Time <150 mS from 95% to 10% rated voltage @ full load (T amb=+25°C) Line and Load Regulation < 0.5% General EMC: -Emissions EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 -Immunity EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard Temperature 7 Storage: -40oC to + 85oC, Operation -25oC to +60oC full power, with linear derating to half power from 60 to 70oC (Convection cooling, no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. MTBF 8 > 550,000 hrs Warranty 5 Year Limited Warranty General Protection/ Safety Protected against continuous short -circuit, continuous overload, continuous open circuit. Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Status Indicators Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200ma/50 Vdc Installation Fusing -Input Internally fused -Output Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Connections Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. Screw torque: 4.4 lb-inch (~ 50 N-cm). Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. Screw torque: 7 lb-inch (~ 80 N-cm). Case Fully enclosed metal housing with fine ventilation grid to keep out small parts. -Free Space 25 mm above and below, 10 mm left and right, 15 mm in front H x W x D inches in (mm) 4.85 × 1.97 × 4.36 (123.0 × 50.0 × 110.0) 4.85 × 2.36 × 4.36 (123.0 × 60.0 × 110.0) Weight lbs (kg) 1.1 (0.50) 1.7 (0.80) SDN-C Specifications (Single Phase) 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. 24-28 Vdc adjustable guaranteed at full load. 5. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 6. Peak current is calculated at 24 Volt levels. 7. Contact tech support for operation at -25oC. 8. Demonstrated through extended life test. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |