Back Button P2CF-08 Datasheet HTML 3Page - Omron Electronics LLC P2CF-08 Datasheet HTML 4Page - Omron Electronics LLC P2CF-08 Datasheet HTML 5Page - Omron Electronics LLC P2CF-08 Datasheet HTML 6Page - Omron Electronics LLC P2CF-08 Datasheet HTML 7Page - Omron Electronics LLC P2CF-08 Datasheet HTML 8Page - Omron Electronics LLC P2CF-08 Datasheet HTML 9Page - Omron Electronics LLC P2CF-08 Datasheet HTML 10Page - Omron Electronics LLC P2CF-08 Datasheet HTML 11Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 15 page
background image
H3CA
H3CA
7
Signal Start
Power is applied continuously. The OFF/ON cycle is initiated at
the leading edge of the start input. The output relay will be OFF
for the set time and then ON for the set time. The timer is reset
when power is disconnected or a reset input is applied.
(AC/DC)
Start signal
Reset signal
Start
3 - 6
(X-C1)
Control
9 - 11
output NO (15-18)
Time-out
indicator
Remaining
time indicator
Power
2 - 10
(A1-A2)
Reset
3 - 7
(X-B1)
t = set time
t-a = less than set time
Mode G
Signal ON-delay/OFF-delay
Power is continuously applied. Timing begins on both the leading
and trailing edges of the start input. The output relay is energized
when the accumulated time from the leading edge equals the set
time. It is also energized for the set amount of time from the
trailing edge of the start input.
(AC/DC)
Start signal
Start
3 - 6
(X-C1)
Control
9 - 11
output NO (15-18)
Time-out
indicator
Remaining
time indicator
Power
2 - 10
(A1-A2)
Reset
3 - 7
(X-B1)
t = set time
t-a = less than set time
Power
Power
Mode H
Signal OFF-Delay (II)
Power is continuously applied. Timing starts at the trailing edge of
the start input. The output relay is energized during timing.
Power
(AC/DC)
Start
3 - 6
(X-C1)
Control
9 - 11
output NO (15-18)
Time-out
indicator
Remaining
time indicator
Power
2 - 10
(A1-A2)
Reset
3 - 7
(X-B1)
t = set time
t-a = less than set time
Start signal
In the schematic diagrams, each thick line indicates the external wiring necessary for the selected operation.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com