| Electronic Components Datasheet Search |
|
PS402-01XX Datasheet(PDF) 8 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PS402-01XX Datasheet(HTML) 8 Page - Microchip Technology |
|
8 / 46 page ![]() PS402-01XX DS21766A-page 8 2003 Microchip Technology Inc. 3.0 OPERATIONAL MODES The PS402 operates on a continuous cycle, as illustrated in Figure 3-1. The frequency of the cycles depend on the power mode selected. There are three power modes: Run, Sample and SLEEP. Each mode has specific entry and exit conditions as listed below. 3.1 Run Mode Whether the PS402 is in Run Mode or Sample Mode depends on the magnitude of the current. The Run and Sample Mode entry-exit threshold is calculated using the following EEPROM data values and formula: +/- X mA = SampleLimit x CFCurr / 16384 SampleLimit is a programmable EEPROM value, and CFCurr is an EEPROM value set by calibration. Entry to Run Mode occurs when the current is more than +/- X mA for two consecutive measurements. Run Mode may only be exited to Sample Mode, not to SLEEP Mode. Exit from Run Mode to Sample Mode occurs when the converted measured current is less than the +/- X mA threshold for two consecutive measurements. Run Mode is the highest power consuming mode. During Run Mode, all measurements and calculations occur once per measurement period. Current, voltage and temperature measurements are each made sequentially during every measurement period. 3.2 Sample Mode Entry to Sample Mode occurs when the converted measured current is less than +/- SampleLimit (EE parameter) two consecutive measurements. Sample Mode may be exited to either Run Mode or SLEEP Mode. While in Sample Mode, measurements of voltage, current and temperature occur only once per NSample counts of measurement periods, where NSample is a programmable EEPROM value. Calculations of state- of-charge, SMBus requests, etc. still continue at the normal Run Mode rate, but measurements only occur once every measurement period x NSample. The minimum value for NSample is two. The purpose of Sample Mode is to reduce power consumption during periods of inactivity (low rate charge or discharge.) Since the analog-to-digital converter is not active except every NSample counts of measurement periods, the overall power consumption is significantly reduced. Configuration Example: Measurement period is 500 ms CFCurr current calibration factor is 12500 SampleLimit is set to 27 NSample is set to 16 Result: Run/Sample Mode entry-exit threshold: 27 x 12500 / 16384 = +/- 20.6 mA During Sample Mode, measurements will occur every: 16 measurement periods of 500 mS = every 8 seconds 3.3 SLEEP Mode Entry to SLEEP Mode can only occur when the measured pack voltage at VC(1) input is below a preset limit set by the EEPROM value SleepVPack (in mV). SLEEP Mode may be exited to Run Mode, but only when one of the wake-up conditions is satisfied. If the voltage measured at the VC(1) input is below the SleepVPack threshold, but the measured current is above the Sample Mode threshold (which maintains Run Mode), then SLEEP Mode will NOT be entered. SLEEP Mode can only be entered from Sample Mode. While in SLEEP Mode, no measurements occur and no calculations are made. The fuel gauge display is not operational, no SMBus communications are recog- nized, and only a wake-up condition will permit an exit from SLEEP Mode. SLEEP Mode is one of the lowest power consuming modes and is used to conserve battery energy following a complete discharge. When in the SLEEP Mode (entry due to low voltage and Sample Mode), there are four methods for waking up. They are voltage level, current level, SMBus activity and I/O pin activity. The EEPROM value WakeUp defines which wake-up functions are enabled, and also the voltage wake-up level. Table 3-1 indicates the appropriate setting. Note that the setting is independent of the number of cells or their configuration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |