8 / 15 page ![]() LINEAR MAGNETIC FIELD SENSORS 8 Most low field magnetic sensors will be affected by large magnetic disturbing fields (>4 - 20 gauss) that may lead to output signal degradation. In order to reduce this effect, and maximize the signal output, a magnetic switching technique can be applied to the MR bridge that eliminates the effect of past magnetic history. The purpose of the Set/Reset (S/R) strap is to restore the MR sensor to its high sensitivity state for measuring magnetic fields. This is done by pulsing a large current through the S/R strap. The Set/Reset (S/R) strap looks like a resistance between the SR+ and SR- pins. This strap differs from the OFFSET strap in that it is magnetically coupled to the MR sensor in the cross-axis, or insensitive, direction. Once the sensor is set (or reset), low noise and high sensitivity field measurement can occur. In the discussion that follows, the term “set” refers to either a set or reset current. When MR sensors exposed to a magnetic disturbing field, the sensor elements are broken up into ramdonly oriented magnetic domains (Figure 4A) that leads to sensitivity degrading. A current pulse (set) with a peak current above minimum current in spec through the Set/Reset strap will generate a strong magnetic field that realigns the magnetic domains in one direction (Figure 4B). This will ensure a high sensitivity and repeatable reading. A negative pulse (Reset) will rotate the magnetic domain orientation in the opposite direction (Figure 4C), and change the polarity of the sensor outputs. The state of these magnetic domains can retain for years as long as there is no magnetic disturbing field present. The on-chip S/R should be pulsed with a current to realign, or “flip”, the magnetic domains in the sensor. This pulse can be as short as two microsecond and on average consumes less than 1 mA dc when pulsing continuously. The duty cycle can be selected for a 2 µsec pulse every 50 msec, or longer, to conserve power. The only requirement is that each pulse only drive in one direction. That is, if a +3.5 amp pulse is used to “set” the sensor, the pulse decay should not drop below zero current. Any undershoot of the current pulse will tend to “un-set” the sensor and the sensitivity will not be optimum. Using the S/R strap, many effects can be eliminated or reduced that include: temperature drift, non-linearity errors, cross-axis effects, and loss of signal output due to the presence of a high magnetic fields. This can be accom- plished by the following process: • A current pulse, Iset, can be driven from the S/R+ to the S/R- pins to perform a “SET” condition. The bridge output can then be measured and stored as Vout(set). • Another pulse of equal and opposite current should be driven through the S/R pins to perform a "RESET" condi- tion. The bridge output can then be measured and stored as Vout(reset). • The bridge output, Vout, can be expressed as: Vout = [Vout(set) - Vout(reset)]/2. This technique cancels out offset and temperature effects introduced by the electron- ics as well as the bridge temperature drift. There are many ways to design the set/reset pulsing circuit, though, budgets and ultimate field resolution will determine which approach will be best for a given application. A simple set/reset circuit is shown in Figure 5. WHAT IS SET/RESET STRAP? The magnitude of the set/reset current pulse depends on the magnetic noise sensitivity of the system. If the minimum detectable field for a given application is roughly 500 µgaussinHMC1001/2,thena3amppulse(min)isadequate. If the minimum detectable field is less than 100 µgauss, then a 4 amp pulse (min) is required. The circuit that generates the S/R pulse should be located close to the MR sensor and have good power and ground connections. The set/reset straps on the Honeywell magnetic sensors are labeled S/R+ and S/R-. There is no polarity implied since this is simply a metal strap resistance. Figure 5—Single-Axis Set/Reset Pulse Circuit (1001) 5V S/R+ 0.2µF 25K 3 4 2 1 5,6 7,8 0.1µF SET RESET RESET Signal should be in RESET state when idle Signal input Manual Switch 6-9V S/R- Easy Axis Permalloy (NiFe) Resistor Random Domain Orientations After a Set Pulse Magnetization After a Reset Pulse Magnetization Fig.4A Fig.4B Fig.4C Figure 4— |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |