Back Button S5935 Datasheet HTML 28Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 29Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 30Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 31Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 32Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 33Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 34Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 35Page - Applied Micro Circuits Corporation S5935 Datasheet HTML 36Page - Applied Micro Circuits Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 32 / 190 page
background image
3-24
S5935
PCI CONFIGURATION REGISTERS
Bit
Description
Table 5. PCI Status Register
15
Detected Parity Error. This bit is set whenever a parity error is detected. It functions independently
from the state of Command Register Bit 6. This bit may be cleared by writing a 1 to this location.
14
Signaled System Error. This bit is set whenever the device asserts the signal SERR#. This bit can be
reset by writing a 1 to this location.
13
Received Master Abort. This bit is set whenever a bus master abort occurs. This bit can be reset by
writing a 1 to this location.
12
Received Target Abort. This bit is set whenever this device has one of its own initiated cycles
terminated by the currently addressed target. This bit can be reset by writing a 1 to this location.
11
Signaled Target Abort. This bit is set whenever this device aborts a cycle when addressed as a target.
This bit can be reset by writing a 1 to this location.
10:9
Device Select Timing. These bits are read-only and define the signal behavior of DEVSEL# from this
device when accessed as a target.
8
Data Parity Reported. This bit is set upon the detection of a data parity error for a transfer involving
the S5935 device as the master. The Parity Error Enable bit (D6 of the Command Register) must be
set in order for this bit to be set. Once set, it can only be cleared by either writing a 1 to this location
or by the assertion of the signal RESET#.
7
Fast Back-to-back Capable. When equal to 1, this indicates that the device can accept fast back-to-
back cycles as a target.
6:0
Reserved. Equal all 0’s.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com