14 / 26 page ![]() MIC4600 DS20005584B-page 14 2016-2020 Microchip Technology Inc. The same energy is dissipated by ROFF, RG, and RG_FET when the driver IC turns the MOSFET off. Assuming RON is approximately equal to ROFF, the total energy and power dissipated by the resistive drive elements is illustrated in Equation 5-7: EQUATION 5-7: The power dissipated inside the driver is equal to the ratio of RON and ROFF to the external resistive losses in RG and RG_FET. Letting RON = ROFF, the power dissipated in the MIC4600 due to driving the external MOSFET is illustrated in Equation 5-8: EQUATION 5-8: 5.8 Total Power Dissipation and Thermal Considerations Total power dissipation in the MIC4600 is equal to the power dissipation caused by driving the external MOSFETs and the quiescent current. EQUATION 5-9: The die temperature can be calculated after the total power dissipation is known, as in Equation 5-10: EQUATION 5-10: 5.9 Decoupling and Bootstrap Capacitor Selection Decoupling capacitors are required for both the low-side (VDD) and high-side (BST) supply pins. These capacitors supply the charge necessary to drive the external MOSFETs and also minimize the voltage ripple on these pins. The capacitor from BST to SW has two functions: it provides decoupling for the high-side driver and is the supply voltage to the high-side circuit while the external MOSFET is on. Ceramic capacitors are recommended because of their low impedance and small size. Z5U type ceramic capacitor dielectrics are not recommended because of the large change in capacitance overtemperature and voltage. A minimum value of 0.1 µF is required for each of the capacitors, regardless of the MOSFETs being driven. Larger MOSFETs may require larger capacitance values for proper operation. Placement of the decoupling capacitors is critical. The bypass capacitor for VDD should be placed as close as possible between the VDD and PGND pins. The bypass capacitor (CB) for the BST supply pin must be located as close as possible between the BST and SW pins. The etch connections must be short, wide, and direct. The use of a ground plane to minimize connection impedance is recommended (refer to the following section for more information). 5.10 Grounding, Component Placement, and Circuit Layout Nanosecond switching speeds and ampere peak currents in and around the MIC4600 drivers require proper placement and trace routing of all components. Improper placement may cause degraded noise immunity, false switching, excessive ringing, or circuit latch-up. Figure 5-3 shows the critical current paths when the driver outputs go high and turn on the external MOSFETs. It also helps demonstrate the need for a low impedance ground plane. Charge needed to turn-on the MOSFET gates comes from the decoupling EDRIVER QG VGS = and PDRIVER QG VGS fS = Where: EDRIVER = Energy dissipated per switching cycle. PDRIVER = Power dissipated per switching cycle. QG = Total gate charge at VGS. VGS = Gate to source voltage on the MOSFET. fS = Switching frequency of the gate drive circuit. PDISSDRIVER PDRIVER RON RON RG RG_FET ++ ------------------------------------------------- = PDISSTOTAL PDISSIQ PDISSDRIVE + = TJ TA PDISSTOTAL + JA = Where: TA = Maximum ambient temperature. TJ = Junction temperature. PDISSTOTAL = Power dissipation of the MIC4600. θJA = Thermal resistance from junction to ambient air. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |