| Electronic Components Datasheet Search |
|
TDA2086 Datasheet(PDF) 4 Page - Mitel Networks Corporation |
|
|
|||||||||||||||||||||||||||||
TDA2086 Datasheet(HTML) 4 Page - Mitel Networks Corporation |
|
4 / 6 page ![]() TDA2086 4 TACHO INPUT DRIVE The TDA2086 requires less than 10 µA (pk) to drive the tacho input (pin 15) and has bidirectional clamping. This makes it possible to connect a tacho pick up coil directly to the device hence minimising component count. A motor may fail to start up if a signal is picked up by a sensitive tacho due to vibration in the rotor caused by elastic sticktion when power is initially applied. This can be easily overcome by incorporating a filtering capacitor across the tacho input. SPECIAL FEATURES Low Supply Current Consumption Due to the low current consumption of the device the power dissipation in the mains dropper resistor may be as low as 1 lW on a 220V AC supply (0 5W on 110V). By incorporating both a shunt and a series voltage regulator in the IC design, a high ripple voltage can be accommodated on the supply smoothing capacitor. The combination of the above two features result in reduced size and a minimum count of components used in the power supply circuitry. Powered Direct from AC Mains or DC Line This device incorporates a shunt regulator (-15V) such that it may be powered from an AC or DC supply via current limiting components or the device may be powered direct from a -12V DC supply. -5V Supply available for Ancillary Circuitry A -5V series regulator is incorporated to provide a smooth supply for the internal analog control functions. This supply may be used externally to power ancillary circuitry such as timing circuits and other logic control circuits etc, as well as driving potentiometers for the analog control inputs. Due to this supply technique, greater symmetry between positive and negative half cycle firing phase angle will result. Low Supply Inhibit Circuit Timing functions and triac gate drive pulses are inhibited until there is sufficient supply voltage across the device to guarantee complete gate drive pulses. This ensures that bulk conduction is established in the triac and correct linear operation of the control system is maintained. Negative Triac Gate Firing Pulses Since the device works with the positive supply as common, the triac gate pulses are negative going. This is an advantage when selecting a suitable triac since most triac manufacturers prefer this drive polarity. The device is designed to give a triac pulse that is greater than 100mA for a period of 50 microseconds with standard pulse timing components (47nF, pin 16). Repeated triac gate pulses are given if the triac fails to latch or becomes unlatched due to motor brush bounce. Well-Defined Control Voltage/Phase Angle (Open Loop) An internal 5V stabiliser circuit is used as the charging voltage for the pulse timing ramp capacitor and as the reference voltage for the speed input potentiometer. This ensures that maximum phase angle can be obtained by adjusting the resistor or capacitor on the pulse timing circuit, without affecting the maximum setting. Average or Peak Load Current Limiting The load current is normally sensed in the positive mains cycle by means of a low impedance resistor in series with the triac and load. The voltage drop across this resistor is converted back into a low current source by a second resistor and fed into the load current sensing input (pin 5) of the IC. In high load current applications where the power dissipated in a series sensing resistor would be unacceptable, a current transformer may be uitilised. The current fed into the sensing input (pin 5) is mirrored by the IC and fed to the inhibit input (pin 8). Peak current limiting can be provided at this point by inserting a resistor between pin 8 and common (pin 3), whereas average current limiting requires the addition of an integrating capacitor. When average current limiting is used the double action of the inhibit circuit is utilised. This has two trip points such that when the first trip point (-1V) is reached the power to the load will be gradually reduced by decreasing the voltage on the ramp capacitor, (the discharge rate being equal but opposite to the soft start), hence reducing the power and providing a constant current drive (producing constant torque) to the motor. When the second trip point (-1 5V) is reached a general reset of all timing functions occurs at a fast rate, hence if a gross overload was suddenly applied to the motor, a rapid reduction in power supplied would result. Since it is not possible to turn the triac off during a cycle, the triac and motor should be chosen to be capable of withstanding one complete mains cycle under the worst overload condition. Peak load current limiting tends to produce a fold back action (of motor speed and torque) at large conduction phase angle. This is due to the peak current initially increasing when the phase conduction angle is reduced at constant load torque. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |