| Electronic Components Datasheet Search |
|
CLS54D Datasheet(PDF) 3 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
CLS54D Datasheet(HTML) 3 Page - Endress+Hauser Group Services AG |
|
3 / 12 page ![]() Indumax CLS54D Endress+Hauser 3 Communication and data processing Communication with the transmitter Always connect digital sensors with Memosens technology to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. Digital sensors can store measuring system data in the sensor. These include the following: • Manufacturer data – Serial number – Order code – Date of manufacture • Calibration data – Calibration date – Cell constant – Delta cell constant – Number of calibrations – Serial number of the transmitter used to perform the last calibration • Operating data – Temperature application range – Conductivity application range – Date of initial commissioning – Maximum temperature value – Hours of operation at high temperatures Dependability Reliability Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter via a . The result: • Automatic error message if sensor fails or connection between sensor and transmitter is interrupted • Immediate error detection increases measuring point availability Maintainability Easy handling Sensors with Memosens technology have integrated electronics that store calibration data and other information (such as total hours of operation and operating hours under extreme measuring conditions). Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: • Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. • Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point . • Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. • The sensor history can be documented on external data carriers and in evaluation programs. Thus, the current application of the sensors can be made to depend on their previous history. Integrity • Measured values cannot be distorted by moisture. • EMC safety provided by screening measures in digital measured value transmission. Input Measured values • Conductivity • Temperature |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |