| Electronic Components Datasheet Search |
|
MP1048EM Datasheet(PDF) 8 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP1048EM Datasheet(HTML) 8 Page - Monolithic Power Systems |
|
8 / 12 page ![]() MP1048 – FULL BRIDGE CCFL CONTROLLER MP1048 Rev. 0.9 www.MonolithicPower.com 8 9/24/2007 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2007 MPS. All Rights Reserved. Table 1—Function Modes Pin Connection Function ABRT DBRT BRS Ratio Analog Mode 0 – 1.2V VCC VCC 3:1 Burst Mode with DC Input Voltage VCC 0 – 1.2V R6 C7 10:1 Burst Mode with External Source VCC PWM VCC Set by Customer Analog and Burst Mode 0 – 1.2V 0 – 1.2V R6 C7 30:1 Analog and Burst Mode with External Source 0 – 1.2V PWM VCC Set by Customer Brightness Polarity Burst: 100% duty cycle is at 1.2V Analog: 1.2V is for maximum brightness Fault Protection Open Lamp: The LV pin (#3) is used to detect whether an open lamp condition has occurred. If the voltage at LV exceeds +1.2V, a pulse of current will pull down on the COMP pin to regulate the lamp voltage. The Fault Timer will be started with a 1µA current source injecting into C2 at the FT pin, while the fault condition persists. If the voltage at the FT pin exceeds 1.2V, then the chip will shutdown. Excessive Secondary Current (Shorted Lamp): The SI pin (#1) is used to detect whether excessive secondary current has occurred. If a fault condition occurs that increases the secondary current, then the voltage at SI will be greater than 1.2V. A pulse of current will pull down on the COMP pin to regulate the secondary current. The Fault Timer will be started with a 65µA current source injecting into C2 at the FT pin while the fault condition persists. If the voltage at the FT pin exceeds 1.2V, then the chip will shutdown and need to be enabled again. Fault Timer: The timing for the fault timer will depend on the sourcing current as described above and the capacitor C2 on the FT pin. The user can program the time for the voltage to rise after the chip detects a “real” fault. When a fault is triggered, the internal voltage (VCC) will collapse from 6V to 0V. If no fault is detected a 1µA current sink will keep FT to 0V. Startup For reliable ignition of the lamp, the operating frequency is swept temporarily toward the unloaded resonant frequency of the tank during startup. This guarantees the strike voltage of the lamp at any temperature due to a resonant topology for switching the outputs and eliminates the need for external ramp timing circuits to ensure startup. Once the strike voltage is achieved, the switching frequency is gradually adjusted to the preset fixed value. The operating frequency before the lamp strikes can be swept as much as 160% of the preset frequency value. Chip Enable The chip has an ON/OFF function, which is controlled by the EN pin (#13). The enable signal goes directly to a Schmitt trigger. The chip will turn ON with an EN = High and OFF with an EN = Low. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |