| Electronic Components Datasheet Search |
|
MP1048EY Datasheet(PDF) 7 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP1048EY Datasheet(HTML) 7 Page - Monolithic Power Systems |
|
7 / 12 page ![]() MP1048 – FULL BRIDGE CCFL CONTROLLER MP1048 Rev. 0.9 www.MonolithicPower.com 7 9/24/2007 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2007 MPS. All Rights Reserved. Careful management of limit conditions provides graceful reduction of lamp power at low supply voltages but allows the loop to recover quickly from an abrupt step in supply voltage. System fault management facilities include an on-chip open-lamp regulator, a transformer secondary peak current regulator and a dual-mode fault timer. By regulating the peak current in the transformer secondary winding, UL1950 can be met for most systems. When the MP1048 is regulating open lamp voltage, it ignores the burst control and runs continuously to ensure either the lamp has a chance to re-ignite or the fault timer can smoothly and accurately time out. If the MP1048 detects an open lamp condition for a time that exceeds the timer interval, it will shutdown until the part is turned off and then turned on again. Similarly, the MP1048 will shutdown if it detects an over-current condition in the secondary for about 2% of the open lamp timer interval. If required, the secondary over-current timeout can be shortened with external components. On-chip current limit protects the MP1048 in case of output fault conditions. FEATURE DESCRIPTION All reference designators refer to the MP1048 Block Diagram, unless otherwise designated. High Efficiency Operation There are two major power losses in a CCFL inverter: switching loss of switches and copper loss of the transformer winding. To reduce switching loss, Zero Current Switching (ZCS as described in US patent 6,114,814) or Zero Voltage Switching (ZVS) are commonly implemented. As shown in Figure 2, ZCS and ZVS require primary current IPRI lagging primary voltage VPRI. With ZVS, since D1 can only conduct at the negative phase of IPRI, the beginning of A & D conduction will only happen at the negative phase of IPRI. Higher phase delay will lead to higher primary RMS current and therefore higher transformer temperature. With ZCS, A & D conduction starts at the zero crossing of IPRI. The MP1048 does not utilize ZVS or ZCS. It implements fast switching to reduce switching loss and operates at the condition that IPRI and VPRI are in phase to reduce primary RMS current. Therefore, higher efficiency than ZVS or ZCS is achieved. A D1 B + VPS IPRI VPRI C D - VPS VPRI: IPRI: ZVS ZCS MP1048 0 0 0 A,D B,C Figure 2—VPRI vs. IPRI Brightness Control The MP1048 can operate in four modes: Analog Mode, Burst Mode with a DC input, Burst Mode with an external PWM or Analog and Burst Mode. The four modes are dependent on the pin connections defined under Pin Functions. Choosing the required burst repetition frequency can be achieved by an RC combination as defined in component selection. The MP1048 has a soft-on and soft-off feature to reduce noise when using burst mode dimming. Analog dimming and Burst dimming are independent of each other and may be used together to obtain a wider dimming range. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |