Electronic Components Datasheet Search
  English  ▼

X  

PCB-CB-232F Datasheet(PDF) 7 Page - BusBoard Prototype Systems Ltd.

Part # PCB-CB-232F
Description  RS-232 to Logic Level Adapter with DB9F Connector and Power LED
PDF  7 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  BUSBOARD [BusBoard Prototype Systems Ltd.]
Direct Link  http://www.busboard.com/
Logo BUSBOARD - BusBoard Prototype Systems Ltd.

PCB-CB-232F Datasheet(HTML) 7 Page - BusBoard Prototype Systems Ltd.

  PCB-CB-232F Datasheet HTML 1Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 2Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 3Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 4Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 5Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 6Page - BusBoard Prototype Systems Ltd. PCB-CB-232F Datasheet HTML 7Page - BusBoard Prototype Systems Ltd.  
Zoom Inzoom in Zoom Outzoom out
 7 / 7 page
background image
BusBoard Prototype Systems - Built for designers
www.BusBoard.com
sales@busboard.com
BPS-DAT-(PCB-CB-232F)-0001 Rev 1.00 Datasheet.doc
RS-232 Signal Levels
The reason a RS-232 interface IC is needed is to convert the 0 and 5 Volt logic levels (or 0 and 3.3V) to
the positive and negative RS-232 levels. The RS-232 voltages were selected in the days of teleprinters
to help transit data reliably over long lengths of cable.
The RS-232 interface converts the conventional 0 to 5 volt signal range (Low/High signals) into two
states called Mark and Space.
Mark is used for the negative state which is from -5 to -15 volts.
It represents a logical 1 (a High signal).
Space is used for the positive state which is from +5 to +15 volts.
It represents a logical 0 (a Low signal).
The RS-232 driver also inverts the signal so that a +5V signal is converted to the negative RS-232
(Marking) state. In Figure 2 below, the upper signal is the logic-level serial data going into the interface
IC, and the lower signal is the RS-232 level signals coming out.
Marking
Bits
Start
Bit
1
1
1
0
0
0
0
0
Stop
Bit(s)
Marking
Bits
Start
Bit
1
1
1
0
0
0
0
0
Stop
Bit(s)
-5 to -15 Volts
+5 to +15 Volts
0 Volts
5 Volts
RS-232 Levels
Logic Levels
Figure 2 RS-232 Signal Levels
RS-232 Data Format
Figure 2 shows the transmit line voltages for an 8 bit word being sent with no parity. The signal is
Marking (logic HI) when no data is being sent.
When a character is transmitted, it begins with a Start Bit which is a Space. It is followed by the 8 bits
of the character. The least significant bit (LSB) is sent first and the most significant bit (MSB) of the
character is sent last. Finally, Stop Bit (a Mark) is sent at the end of the character. If parity is used, a
parity bit is added before the Stop Bit.
Figure 2 shows the binary value 00100011 being sent, which is Hex 0x23, decimal 35, which is the ‘#’
octothorpe character.



Html Pages

1 2 3 4 5 6 7


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com