4 / 18 page ![]() Type 8221 4 | 18 Visit product website 1. General technical data 1.1. About the probe The probes are based on the 2 or 4 electrode principle. The technical data depends on the probe variant. The common technical data are described in this chapter and further information on the specifics can be found in chapter “2. Product variants” on page 6. 1.2. 4-electrode conductivity probe Product properties Material Make sure the device materials are compatible with the fluid you are using. Further information can be found in chapter “4.1. Bürkert resistApp” on page 9. Depending on the probe variant. Further information on the materials can be found in chapter “2. Product variants” on page 6. Seal EPDM (conform to FDA - 21CFR177.2600) Surface quality Ra < 0.4 μm (15 μin.), electro-polished (wetted metal surfaces) Dimensions Further information can be found in chapter “5. Dimensions” on page 10. Measuring element 4-electrode Temperature sensor Pt1000 Performance data Linearity 1.) (relative) ± 0.5…5 % Medium data Fluid temperature Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Fluid pressure Depending on the probe variant. Further information can be found in chapters “2. Product variants” on page 6. and “6.2. Pressure temperature diagram” on page 14. Process/Pipe connection & communication Process connection Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Electrical connection Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Approvals and conformities Directives CE directive Further information on the CE Directive can be found in chapter “3.3. Standards” on page 8. Pressure equipment directive Complying with article 4, paragraph 1 of 2014/68/EU directive Further information on the pressure equipment directive can be found in chapter “3.4. Pressure Equipment Directive (PED)” on page 9. Foods and beverages/Hygiene • FDA declaration of conformity (only for variant with PEEK armature and EPDM seal) • USP class VI declaration Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Materials Inspection certificate 3.1 Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Others On request: 2-point calibration certificate Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Environment and installation Ambient temperature Depending on the probe variant. Further information can be found in chapter “2. Product variants” on page 6. Degree of protection according to IEC/EN 60529 IP67, with connected device, inserted and screwed cable plug 1.) If only one cell constant is used over the entire range, uncertainties of ± 5 % may occur. If the measured calibration value is close to the measured conductivity value of the solution used, a measurement deviation of ± 0.5 % can be achieved. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |