  791002002 Datasheet HTML 1Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 2Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 3Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 4Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 5Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 6Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 7Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 8Page - Wurth Elektronik GmbH & Co. KG, Germany. 791002002 Datasheet HTML 9Page - Wurth Elektronik GmbH & Co. KG, Germany. Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 11 page
background image
Description:
WE-RCDS 791002002 is a residual current detection sensor designed for wallbox application to meet IEC 62955: 2018.
It is a open loop fluxgate current sensor with toroidal core and designed for PCB mounting.
Features:
•
Compact design for PCB board mounting
•
Cable through hole
•
DC 6mA residual direct current detecting RDC-M-Module for mode 3 EV charging
•
Digital open-drain output, 6mA DC trip indication
•
PWM signal output for system fault indication
•
Supply voltage drop monitoring
•
Designed to meet standard: IEC 62955: 2018
•
Module Software certified according to ANSI/UL 1998, Class 1
•
Partially EMC tested according to IEC 62955: 2018 and EN 60730-1
Application:
Residual current detection sensor for stationary EV charging devices.
Electrical Properties:
General Description of Senor Function:
The sensor is sensitive to DC current and can be used for fault current detection in EV-charging applications to meet
IEC 62955: 2018. In the event of a DC fault current, PIN 2 will change the state from a low level to a high impedance level state.
The PWM signal output of PIN 4 is for system fault indication.
The sensor is only designed to meet the switch-off characteristic of the IEC62955: 2018 standard (monitoring the residual current).
An additional driver-circuit must be used for driving RCBO, RCCB or circuit breaker as defined in IEC62955: 2018
Symbol
Description
Min. value
Typ. value
Max. value
unit
IP
Primary rated current (1phase / 3phase)
80 / 40
A
I∆DC
Residual DC operating current
6
mA
I∆DC_tol
Trip tolerance
3
4.6
6
mA
I∆R DC
Recovery current level for I∆DC
(absolute value DC)
2.5
mA
fBW
Detection frequency range
DC
PWM
Heartbeat signal frequency for system
monitoring
940
1000
1060
Hz
Heartbeat signal duty cycle for system
monitoring
49%
50%
51%
VPWM_out
PWM output voltage
4.7
V
VTEST-IN, low
TEST-IN input voltage, low level
0.6
V
VTEST-IN, high
TEST-IN input voltage, high level
3.1
V
VTRIP, low
TRIP output voltage, low level
0.4
V
VTRIP, high
TRIP output voltage, high level
+Vcc
V
General Information:
Operating Temperature
-40 °C up to 105 °C
Storage Condition
0 °C up to + 40 °C; up to 75 % RH
Test Conditions of Electrical Properties: +20 °C, 33 % RH if not specified differently
CHECKED
AlMo
REVISION
000.001
DATE (YYYY-MM-DD)
2023-07-04
GENERAL TOLERANCE
DIN ISO 2768-1c
PROJECTIO
N METHOD
DESCRIPTION
WE-RCDS Residual Current
Detection Sensor
ORDER CODE
791002002
SIZE/TYPE
Vertical
BUSINESS UNIT
eiSos
STATUS
Valid
PAGE
2/11
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos
GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation
checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.



Html Pages

1 2 3 4 5 6 7 8 9 10 11


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com