Back Button SAA7282ZP Datasheet HTML 13Page - NXP Semiconductors SAA7282ZP Datasheet HTML 14Page - NXP Semiconductors SAA7282ZP Datasheet HTML 15Page - NXP Semiconductors SAA7282ZP Datasheet HTML 16Page - NXP Semiconductors SAA7282ZP Datasheet HTML 17Page - NXP Semiconductors SAA7282ZP Datasheet HTML 18Page - NXP Semiconductors SAA7282ZP Datasheet HTML 19Page - NXP Semiconductors SAA7282ZP Datasheet HTML 20Page - NXP Semiconductors SAA7282ZP Datasheet HTML 21Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 25 page
background image
July 1993
17
Philips Semiconductors
Product specification
Terrestrial Digital Sound Decoder (TDSD2)
SAA7282
Notes
1. Outputs OPL and OPR are measured with external components as recommended in Fig.11.
2. Total analog performance is limited by dynamic range of the NICAM 728 system. Due to compansion the quantization
noise is never lower than approximately -62 dB with respect to the input level.
3. Measured with a -30 dB, 1 kHz NICAM 728 input signal.
4. Note that a transmitter must internally provide at least a hold time to bridge the undefined region (max. 300 ns) of the
falling edge of SCL.
5. If a fast I2C-bus device is used in an up to 100 kbit/s I2C-bus system, then the requirement tSU;DAT ≥250 ns is always
fulfilled if this device cannot stretch the LOW level of the SCL signal. If a device stretches the LOW level of the SCL
signal, then data to SD9A must be asserted (tRD(max) + tSU;DAT) = 1000 + 250 = 1250 ns before the SCL signal is
released to be compatible with the up to 100 kbit/s I2C-bus specification.
6. The output fall time is measured between 3.0 V and 1.5 V for a bus capacitance of 400 pF and an active pull-up.
SDA with respect to SCL (see Fig.8)
fSCL
SCL clock frequency
0
−
400
kHz
tBUF
bus free time
1300
−−
ns
tHD;STA
start code hold time
600
−−
ns
tLOW
SCL clock LOW time
1300
−−
ns
tHIGH
SCL clock HIGH time
600
−−
ns
tSU;STA
start code set-up time
600
−−
ns
tHD;DAT
data hold time
note 4
0
−−
ns
tSU;DAT
data set-up time
note 5
100
−−
ns
tr
SDA and SCL rise time
50
−
300
ns
tf
SDA and SCL fall time
50
−
300
ns
tSU;STO
stop code set-up time
600
−−
ns
tof
output fall time
note 6
50
−
200
ns
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com