17 / 22 page ![]() DER-35 Cell Phone Adapter TNY264 April 5, 2004 Page 17 of 22 Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com 10.3 Drain Voltage and Current Start-up Profile Figure 17 - 90 VAC Input and Maximum Load. Upper: IDRAIN, 0.1 A / div. Lower: VDRAIN, 100 V & 5us / div. Figure 18 - 264 VAC Input and Maximum Load. Upper: IDRAIN, 0.1 A / div. Lower: VDRAIN, 200 V & 2us / div. 10.4 Load Transient Response (75% to 100% Load Step) In the figures shown below, the oscilloscope was triggered using the load current step as a trigger source. Figure 19 – Transient Response, 115 VAC, 75-100- 75% Load Step. Top: Load Current, 0.2 A/div. Bottom: Output Voltage 200 mV, 1ms / div. Figure 20 – Transient Response, 230 VAC, 75-100- 75% Load Step Upper: Load Current, 0.2 A/ div. Bottom: Output Voltage 200mV, 1ms / div. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|