17 / 28 page ![]() 19-Jul-2005 EP68 3.3 V, 2 A DC-DC Power Supply 10.4 Load Transient Response (75% to 100% Load Step) In the following two oscilloscope screen shots (Figures 17 and 18), signal averaging was used to more clearly capture the output voltage response to a load transient. Averaging minimizes the appearance of the 400 kHz switching ripple in the output voltage scope plot. The load current step was used to trigger the horizontal sweep of the oscilloscope. Figure 17 - Transient Response, 36 VDC, 75-100-75% Load Step. Top: Load Current, 1 A / div. Bottom: Output Voltage, 20 mV, 500 µs / div. Figure 18 - Transient Response, 57 VDC, 75-100-75% Load Step. Top: Load Current, 1 A / div. Bottom: Output Voltage, 20 mV, 500 µs / div. Page 17 of 28 Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|