| Electronic Components Datasheet Search |
|
PM8610 Datasheet(PDF) 95 Page - PMC-Sierra, Inc |
|
|
|||||||||||||||||||||||||||||
PM8610 Datasheet(HTML) 95 Page - PMC-Sierra, Inc |
|
95 / 338 page ![]() SBS Telecom Standard Product Data Sheet Preliminary Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use 95 Document ID: PMC-2000168, Issue 3 COLUMN_MODE The COLUMN_MODE bit selects between column switching and DS0 switching. When COLUMN_MODE is set to a logic one, column switching is enabled and the SBS is configured to switch columns within the SBI336 or TelecomBus. When COLUMN_MODE is set to a logic zero, DS0 switching is enabled and the SBS is configured to switch DS0’s within the SBI336 bus. DS0 switching is not permitted in TelecomBus mode. PHY_SBI The PHY_SBI bit configures the direction of the JUST_REQ[4:1] input/output signals on the incoming and outgoing buses. When PHY_SBI is set to a logic one, the SBS is configured to be connected to a PHY device and the JUST_REQ[4:1] signal is an input. When PHY_SBI is set to a logic zero, the SBS is configured to be connected to a Link layer device and the JUST_REQ[4:1] signal is an output. MF_48 The MF_48 bit selects between 4 frame multiframe mode or 48 frame multiframe mode on the SBI336 bus. When MF_48 is a logic one, 48 frame mode is selected. IC1FP is expected once every 48 frames and OC1FP is output every 48 frames, indicating CAS signaling multiframe alignment. When MF_48 is a logic zero, 4 frame mode is selected. IC1FP is expected once every 4 frames and OC1FP is output every 4 frames. This bit has no effect when in TelecomBus mode (TELECOM_BUS = ‘b1). TELECOM_BUS The TELECOM_BUS bit selects between TelecomBus and SBI bus modes on the incoming and outgoing buses. When TELECOM_BUS is set to a logic one, TelecomBus mode is selected and all frame pulses must mark C1J1V1 positions. When TELECOM_BUS is set to a logic zero, SBI bus mode is selected and the all frame pulses only mark the C1 position. 19M_BUS The 19M_BUS bit selects between 19 MHz and 77 MHz mode on the incoming and outgoing buses. When 19M_BUS is set to a logic zero, 19 MHz mode is selected and 4 separate 19 MHz buses are used. When 19M_BUS is set to a logic one, 77 MHz mode is selected and a single 77 MHz bus is used. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |