Protection Degree / IP Rating**:
IP67
Pollution Degree:
3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distance:
acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage Category:
II acc. to DIN EN 60664-1 (VDE 0110-1)
Materials
Contact Base Material:
CuZn
Contact Plating:
Cu/Au
Contact Bearer Material:
PBT
Contact Bearer Color:
white
Flammability Class (Contact Bearer):
UL 94 V0
Molded Body Material:
TPU
Molded Body Color:
black
Flammability Class (Molded Body):
UL 94-HB
Attachment Material:
CuZn, nickel-plated
O-Ring Material:
NBR
Cable Data
Cable Number:
256
Conductor Size:
8x0.5mm² + 3x1.0 mm²
Number of Wires:
11
Minimal Bending Radius (Fixed Inst):
˃ 5 x D
Minimal Bending Radius (Flexible Inst):
˃ 10 x D
Cycles (Bending):
˃ 2 M
Conductor material:
Cu
Cable Jacket Material:
PUR
Cable Jacket Color:
black
Cable Diameter D:
Ø 9.30 ±0.20 mm
Wire Insulation Material:
PP
Insulated Wire Diameter:
8x Ø1.45 mm + 3x Ø1.95 mm
Ambient Temperature (Fixed Installation): -50°C to +80°C
Ambient Temperature (Flex Installation):
-25°C to +80°C
Ambient Temperature (Drag Chain Inst):
-25°C to +60°C
UL Cable Type:
AWM: 20549
Flammability Class (Cable Jacket):
DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2; flame-retardant
Safety & Environmental Compliance
RoHS Compliant:
yes
Resistances
Halogenfree:
DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1
Notes
Note Derating:
* Notice derating
Protection Degree / IP Rating Note:
** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Note:
Do not connect / disconnect under load.
Particularities:
When the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54.
Variants
Item #
Item Description
Cable Length
84359
RSWU 12-256/5 M
5 m
6742
RSWU 12-256/7 M
7 m
934636560 RSWU 12-256/10 M 10 m
934636561 RSWU 12-256/15 M 15 m
934637085 RSWU 12-256/20 M 20 m



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com