15 / 43 page ![]() HT46R32/HT46R34 Rev. 1.10 15 March 16, 2007 In the case of a timer/event counter OFF condition, writ- ing data to the timer/event counter preload register will also reload that data to the timer/event counter. But if the timer/event counter is turned on, data written to it will only be kept in the timer/event counter preload register. The timer/event counter will still operate until an over- flow occurs. When the timer/event counter is read, the clock will be blocked to avoid errors. As clock blocking may results in a counting error, this must be taken into consideration by the programmer. Bit0~bit2 of the TMRC register can be used to define the pre-scaling stages of the internal clock sources of the timer/event counter. The definitions are as shown. The overflow signal of timer/event counter can be used to generate the PFD signal. Input/Output Ports There are 19 bidirectional input/output lines in the microcontroller, labeled as PA, PB, PC and PD, which are mapped to the data memory of [12H], [14H], [16H] and [18H] respectively. All of these I/O ports can be used for input and output operations. For input opera- tion, these ports are non-latching, that is, the inputs must be ready at the T2 rising edge of instruction ²MOV A,[m] ² (m=12H, 14H, 16H or 18H). For output operation, all the data is latched and remains unchanged until the output latch is rewritten. Each I/O line has its own control register (PAC, PBC, PCC, PDC) to control the input/output configuration. With this control register, CMOS output or Schmitt trig- ger input with or without pull-high resistor structures can be reconfigured dynamically (i.e. on-the-fly) under soft- ware control. To function as an input, the corresponding latch of the control register must write ²1². The input source also depends on the control register. If the con- trol register bit is ²1², the input will read the pad state. If the control register bit is ²0², the contents of the latches will move to the internal bus. The latter is possible in the ²read-modify-write² instruction. V D D M U X M U X P F D E N ( P A 3 ) W a k e - u p o p t i o n T M R f o r P A 4 O n l y I N T f o r P A 5 O n l y S y s t e m W a k e - u p ( P A o n l y ) R e a d D a t a R e g i s t e r P A 3 P F D ( P D 0 o r P W M ) D Q C K S C o n t r o l B i t P u l l - H i g h O p t i o n D a t a B u s W r i t e C o n t r o l R e g i s t e r C h i p R e s e t R e a d C o n t r o l R e g i s t e r W r i t e D a t a R e g i s t e r D a t a B i t P A 0 ~ P A 2 P A 3 / P F D P A 4 / T M R P A 5 / I N T P A 6 , P A 7 P B 0 / A N 0 ~ P B 3 / A N 3 P B 4 ~ P B 7 P D 0 / P W M 0 P D 1 / P W M 1 P D 2 P D 3 Q D Q C K S Q Input/Output Ports T M 1 T M 0 T M R T E T M 1 T M 0 T O N P u l s e W i d t h M e a s u r e m e n t M o d e C o n t r o l 8 - B i t T i m e r / E v e n t C o u n t e r P r e l o a d R e g i s t e r 8 - B i t T i m e r / E v e n t C o u n t e r D a t a B u s R e l o a d O v e r f l o w t o I n t e r r u p t 1 / 2 P F D 8 - s t a g e P r e s c a l e r 8 - 1 M U X f S Y S f I N T P S C 2 ~ P S C 0 ( 6 + 2 ) C o m p a r e P W M T o P D 0 C i r c u i t Timer/Event Counter |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |