12 / 22 page ![]() 12 2006 Semtech Corp. www.semtech.com SC1480 POWER MANAGEMENT Applications Information (Cont.) 1.3W 50 85 150 T T P JA A J T = − = − = θ Each FET must not exceed 1.3W of power dissipation. MOSFET Power Dissipation Worst-case conduction losses occur at the duty factor extremes. For the high-side MOSFET, the worst-case conduction power dissipation occurs at minimum battery voltage: ) ON ( DS LOAD 2 MIN IN OUT DUC R I ) ( V V P • • = Typically, a small high-side MOSFET is selected to reduce switching losses at high input voltages. However, the RDS(ON) limits how small the MOSFET can be. Another element of loss in the upper MOSFET is the switching loss, especially at high input voltages, those seen when the AC adaptor is applied. The upper MOSFET switching losses can be estimated as follows: GATE LOAD ) MAX ( IN 2 RSS DUS I I f V C P • • • = Where CRSS is the reverse transfer capacitance of the upper MOSFET and IGATE is the peak gate-drive source/ sink current which is approximately 1A for the SC1480. For the low-side MOSFET the there are only conduction loses to be concerned about since the commutation diode is active while the lower MOSFET switches. The worst- case power dissipation occurs at maximum battery voltage: ) ON ( DS LOAD 2 MAX IN OUT DLC R I ) ( V V - 1 P • • = Adding up the power dissipation for each MOSFET can now proceed and the total for each MOSFET should not exceed 1.3W which was calculated earlier to be the maximum power dissipation under worst-case conditions. Dropout Performance The output voltage adjust range for continuous- conduction operation is limited by the fixed 500nS (maximum) minimum off-time one-shot. For best dropout performance, use the slowest on-time setting of 200kHz. When working with low input voltages, the duty-factor limit must be calculated using worst-case values for on and off times. The IC duty-factor limitation is given by: ) ( T ) ( T ) ( T DUTY MAX OFF MIN ON MIN ON + = Be sure to include inductor resistance and MOSFET on- state voltage drops when performing worst-case dropout duty-factor calculations. Layout Guidelines As with any high frequency switching regulator, it is advisable to practice a careful layout strategy. This includes keeping loop area as small as possible. And properly decoupling lines that pull large currents in short periods of time. To keep loop area small always use a ground plane and if possible split the plane in two areas, signal GND and power GND, then tie the two together at one point. Be sure that high current paths have low inductance by making trace widths wide where possible. The SC1480 pin-outs contain digital signals on the right and analog signals on the left side of the device. This facilitates the isolation of digital and analog signals enabling effective layout of the device. In summary follow these guidelines for good PC board layout:: • Keep high-current paths short, especially at the ground terminals. • Tie AGND and PGND together close to the IC. • Keep the power traces and load connections short. This practice is essential for high efficiency. Using thick copper PC boards (2oz vs 1oz) can enhance full-load efficiency by 1% or more. • Connect the ILIMIT resistor as close to the lower MOSFET drain as possible, and keep the resistance distance from the ILIM pin to the drain short. This will improve current limit accuracy. 1480 System DC Accuracy Two IC parameters effect system DC accuracy, the error comparator offset voltage, and the switching frequency variation with line and load. The 1480 regulates to the REFOUT voltage not the REFIN voltage. Since DDR specifications are written with respect to REFOUT, the offset of the reference buffer does not create a regulation error. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |