Electronic Components Datasheet Search
  English  ▼

X  

010760 Datasheet(PDF) 2 Page - Campbell Scientific United Kingdom

Part # 010760
Description  2D Ultrasonic Anemometers
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  CAMPBELL [Campbell Scientific United Kingdom]
Direct Link  https://www.campbellsci.co.uk/
Logo CAMPBELL - Campbell Scientific United Kingdom

010760 Datasheet(HTML) 2 Page - Campbell Scientific United Kingdom

  010760 Datasheet HTML 1Page - Campbell Scientific United Kingdom 010760 Datasheet HTML 2Page - Campbell Scientific United Kingdom  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.co.uk | www.campbellsci.eu
UK | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | SE ASIA | SOUTH AFRICA | SPAIN | USA
© 2012
Campbell Scientific
September 26, 2017
Diameter: 14.2 cm (5.6 in.)
Length: 16.0 cm (6.3 in.)
Weight: 0.5 kg (1.1 lb)
Operating Humidity: < 5% to 100% RH
Temperature Range
Operating: -35° to +70°C
Storage: -40° to +80°C
Input Voltage: 9 to 30 Vdc
Typical Current Drain
WindSonic1: ~9 mA continuous
WindSonic4: <10 mA @ 12 V
Measurement Frequency: 40 Hz block averaged to a 1 Hz
output frequency
Output Parameters: Polar (direction and speed) or orthogonal
(U
x and Uy wind)
Output Signal
WindSonic1: RS-232
WindSonic4: SDI-12 version 1.3
WindSonic1 Maximum Cable Capacitance: 2500 pF
Maximum Cable Lengthb
WindSonic1: 15 m (50 ft)
One WindSonic4 Connected to One Port: 91 m (300 ft)
Two to Ten WindSonic4s Connected to One Port:
60 m (200 ft)
Wind Direction
Range: 0º to 359° (no dead band)
Accuracy: ±3°
Resolution: 1°
Wind Speed
Range: 0 to 60 m s-1
Accuracy: ±2% @ 12 m s-1
Resolution: 0.01 m s-1
Specifications
Ordering Information
2D Ultrasonic Anemometers
WINDSONIC1 Gill 2D Sonic Wind Sensor with RS-232
Output.
WINDSONIC4 Gill 2D Sonic Wind Sensor with SDI-12
Output.
Cable
Standard cable length 3 m, other lengths available from 5 m
in multiples of 5 m.
010760 WindSonic mounting kit for mounting onto a
CM200 series crossarm.
b
Contact Campbell Scientific if longer cable lengths are required.
Typical Applications
Environmental Studies/Wind Resource Surveys
Agriculture
Pollution Control
Portable/Roadside Weather Stations
HVAC
Marine Environments
Alignment and Mounting Details



Html Pages

1 2


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com