  APC18T12 Datasheet HTML 1Page - Astec America, Inc APC18T12 Datasheet HTML 2Page - Astec America, Inc APC18T12 Datasheet HTML 3Page - Astec America, Inc APC18T12 Datasheet HTML 4Page - Astec America, Inc APC18T12 Datasheet HTML 5Page - Astec America, Inc APC18T12 Datasheet HTML 6Page - Astec America, Inc APC18T12 Datasheet HTML 7Page - Astec America, Inc APC18T12 Datasheet HTML 8Page - Astec America, Inc APC18T12 Datasheet HTML 9Page - Astec America, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 10 page
background image
Technical Reference Notes
APC18T12 Series
MODEL: APC18T12 SERIES
SHEET 4 OF 10
NOVEMBER 4, 2004 - REVISION 00
Electrical Specifications (continued)
OUTPUT SPECIFICATIONS
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Response
8 (C
O = 10uF
Tantalum + 1uF Ceramic)
Load Change of 50% step
anywhere between 10% to 100%
of rated load
Peak Deviation
Settling Time to VO, Nom <5%
Peak deviation
∆I
O/∆t
All
-
-
-
-
-
-
2.5
250
100
-
300
150
A/
µs
mV
µs
Dynamic Response
8 (C
O = 150uF
x2 Special Polymer Aluminum
Capacitors)
Load Change of 50% step
anywhere between 10% to 100%
of rated load
Peak Deviation
Settling Time to VO, Nom <5%
Peak deviation
∆I
O/∆t
All
2.5
150
150
200
200
A/
µs
mV
µs
Output Voltage Trim Range
9
All
0.75
5.50
V
Remote Sense
10
All
-
10%
V
NOTE: 1. The converter is not internally fused. Recommended external fuse, Cooper Bussman 6125FA12A or
equivalent
2. External input capacitance required. See Figure 1.
4. Refer to Appendix A3 for the output ripple and Noise Test Measurement Setup.
5. Output current limited by 80W/Vo. Output Power Derating applies at elevated temperature. See Appendix
B for the Thermal Derating Curves.
6. OCP and OTP are in hiccup mode. The converter will auto restart without the need to recycle the input
voltage or toggle the enable signal and once the fault is removed. Vo higher than 1.5V, true OCP exists.
Vo less than 1.5V, OTP is used for OCP. Over current of not higher 150% for Vo less than 1.5V is
recommended. Typical overload condition is 150% or 27A. The module with Vo < 1.5V may not be
survival from over current exceeding 30A.
8. Load step response shall be measured at the load side of the output capacitors. See Appendix A4 for
the output and input cap requirement.
9. See appropriate Trim Equation and configuration in Appendix A6.
10. The combination of remote sense and output trim adjust cannot exceed 5.5V.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com