C1H Datasheet(PDF) 2 Page - Bel Fuse Inc.

Part # C1H
Description  High Current Rated Fast Acting Chip Fuse
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  BEL [Bel Fuse Inc.]
Direct Link  http://www.belfuse.com
Logo BEL - Bel Fuse Inc.

C1H Datasheet(HTML) 2 Page - Bel Fuse Inc.

  C1H Datasheet HTML 1Page - Bel Fuse Inc. C1H Datasheet HTML 2Page - Bel Fuse Inc. C1H Datasheet HTML 3Page - Bel Fuse Inc. C1H Datasheet HTML 4Page - Bel Fuse Inc.  
Zoom Inzoom in Zoom Outzoom out
 2 / 4 page
background image
Type C1H
2 / 4
Bel Fuse Inc.
300 Executive Drive, Suite 300
West Orange, NJ 07052 USA
+1 201.432.0463
Bel.US.CS@belf.com
belfuse.com/circuit-protection
© 2025 Bel Fuse, Inc.
Rev. C1H Feb2025
Temperature Derating Curve
Average Time Current Curve
Electrical Specifications
Part Number
Ampere
Rating
(A)
Marking
Code
Nominal
Cold
Resistance
(ohms)
Maximum
Volt-drop
@100% In
(Volt) max.
Voltage and
Interrupting
Ratings
Nominal
Melting I²T
@10 In
(A² Sec)
Maximum
Power
Dissipation
@100% In
(W)
Agency
Approvals
0685H9100-XX
10A
10
0.0039
0.047
See Table of
Safety Approvals
on Page 1 for
Voltage and
associated
Interrupting
Ratings
5.9
0.47
Y
0685H9120-XX
12A
12
0.0032
0.047
8.0
0.56
Y
0685H9150-XX
15A
15
0.0026
0.050
13.5
0.75
Y
0685H9200-XX
20A
20
0.0019
0.052
28.5
1.04
Y
0685H9250-XX
25A
25
0.0014
0.050
53.4
1.25
Y
0685H9300-XX
30A
30
0.0011
0.053
80.5
1.59
Y
Consult manufacturer for other ratings
NOTES: Test Conditions
All C1H test, as well as the UL Component investigation, were conducted with fuse samples soldered on a PCB (1.6mm thick) test board with
copper traces measuring 0.1 mm
(100μum) nominal thickness (3 oz.clad), 10mm wide and 100 mm overall length.
Device designed to be mounted with marking facing up.
Device designed to carry rated current for 4 hours minimum. It is recommended that device be operated continuously at no more than 80% of
rated current when in a +25°C ambient, with further derating at elevated ambient temperatures.
Caution
Minimum fusing point
C1H Series fuses are NOT intended to be operated at currents between 100% and 350% of ampere rating. Prolonged operation at currents in
this range may result in overheating of the fuse and/or desoldering of the fuse from the PCB pad.
Specifications subject to change without notice



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com