| Electronic Components Datasheet Search |
|
AFE4960P Datasheet(PDF) 1 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AFE4960P Datasheet(HTML) 1 Page - Texas Instruments |
|
1 / 10 page ![]() AFE4960 Two-Channel ECG, Respiration and Pace Pulse Detection Analog Front End (AFE) for Clinical Wearables 1 Features • Supports ECG and respiration impedance measurement; configurable as 2-channel ECG or 1-channel ECG + 1-channel respiration • Can be used in IEC 60601-2-47:2012/(R)2016 and IEC 60601-2-27:2011(R)2016 compliant systems • 222 μA/channel while operating as 2-channel ECG • Integrated Pace pulse detection on 1 channel • Supports a 3-lead ECG, extendable to 5 leads or higher by operating two or more AFEs in parallel • PPG signal chain for SpO2, Heart rate and PTT • ECG signal chain: – Single channel ECG acquisition up to 2.048 kHz – 2 channel ECG acquisition up to 1.36 kHz/ channel – RLD output to set body bias through third electrode – Programmable INA gain from approximately 2 to 12 – >1 GΩ input impedance, CMRR > 100 dB – Input noise (0.5-150 Hz): 13 µVpp at INA gain of 3; 5 μVpp at INA gain of 12 – Integrated 370 Hz anti-aliasing low pass filter – Mode for continuous lead on/off detection – Mode for lead impedance measurement • Bio-Z signal chain: – Measurement of Bio-impedance over excitation frequency from 30 kHz to 100 kHz – Sine wave or square wave excitation – Respiration impedance measurement: 45 mΩ- pp noise on a baseline impedance of 2 kΩ • Dual channel ECG channel: – Bio-Z receiver configurable as a 2nd ECG channel • PPG Signal Chain – Supports acquisition of up to 24 PPG signals – Flexible allocation of 4 LED, 4 PD in each phase – 8-Bit LED Current control up to 250 mA – Low noise current DAC at input to cancel DC – Trans-impedance Gain: 3.7 kΩ to 1 MΩ – Filter to reduce sensor’s optical noise bandwidth • External clock and internal oscillator modes • FIFO with 128-sample Depth, 24-bit word • SPITM, I2C interfaces: Selectable by pin • 2.6-mm × 2.6-mm DSBGA, 0.4-mm Pitch • Supplies: Rx:1.7-1.9 V, IO:1.7-1.9 V, Tx: 3.0-5.5 V 2 Applications • Wireless patches for in-patient and out-patient monitoring • Event monitors for arrhythmia detection • Hand-held ECG monitor • Portable multi-lead ECG • Patient vital sign monitoring: holter, event, stress and telemedicine • SpO2 & Heart rate, and PTT-based blood pressure through synchronized ECG, PPG 3 Description The AFE4960P supports synchronized signal acquisition of ECG, PPG and bio-impedance signals. A PPG signal chain comprises of a current driver for LEDs and a receiver that senses the signal from PDs. The AFE can be configured as either a 2-channel ECG receiver or as a 1-channel ECG receiver and a Respiration impedance channel. The AFE signal chains can interface in a flexible manner to up to 4 electrodes. The AFE has AC and DC Lead biasing and lead on/off detection. Pacemaker pulse detection is supported on one channel. All the signal chain outputs are converted by a single ADC in well-defined time slots and stored as 24-bit words in a 128-sample FIFO which can be read out using a SPI or an I2C interface. The AFE4960P can be used to realize a 3-lead ECG system along with SpO2. Device Information PART NUMBER PACKAGE(1) BODY SIZE (NOM) AFE4960P DSBGA (YBG 36) 2.6 mm x 2.6 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. 128-FIFO SPI, I2C CLK_I,CLK_Q DEMOD DEMOD ADC PACE DETECT LEAD-OFF DET PLL 7b DAC DDS INA LPF LPF INA LPF RESP1 ECG1 RESP2 ECG2 RESP3 ECG3 RESP4 ECG4 Timing Engine OSC Analog signal conditioning for Pace detect Pace Detect CLK_I,CLK_Q LEAD- ON DET ECG CHANNEL 1 BIO-Z TRANSMIT PACE DETECT ECG CHANNEL 2/ BIO-Z RECEIVE HPF1 ECG_RLD Attenuator + – TIA AACM NOISE FILTER PPG RECEIVE PPG TRANSMIT PPG_INP1 PPG_INM1 PPG_INP2 PPG_INM2 PPG_INP3 PPG_INM3 PPG_INP4 PPG_INM4 Block Diagram AFE4960P SBASAL5 – MAY 2022 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. |
Similar Part No. - AFE4960P |
|
Similar Description - AFE4960P |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |