| Electronic Components Datasheet Search |
|
FPP Datasheet(PDF) 4 Page - TT Electronics. |
|
|
|||||||||||||||||||||||||||||
FPP Datasheet(HTML) 4 Page - TT Electronics. |
|
4 / 4 page ![]() © TT Electronics plc Issue B 7/2017 Page 4 TT Electronics | Roxspur Measurement & Control Ltd 2 Downgate Drive, Sheffield, S4 8BT, England |Ph: +44(0)114 244 2521 www.roxspur.com | sales@roxspur.com General Note TT Electronics reserves the right to make changes in product specification without notice or liability. All information is subject to TT Electronics’ own data and is considered accurate at time of going to print. Platon Averaging Pitot Tube: Flo-Bar DS1710 Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. Head Office: 2 Downgate Drive, Sheffield, S4 8BT, England Tel: +44(0)114 244 2521 Fax: +44(0)114 243 4838 READOUT OPTIONS Differential Pressure Transmitter The most frequently used measurement system with a Flo-Bar flow sensor is a conventional DP transmitter, either mounted directly on the Flo-Bar manifold, or separately mounted and connected to the Flo-Bar via impulse tubes. Micro-Bar Electronics For dry gas flow measurement the Micro-Bar low range differential pressure transmitter and alarm, is specifically designed for flow display on Flo-Bar installations. This provides 4-20mA and totaliser pulse outputs. Ask for Data Sheet DS 1720. Flow DP Gauge Differential pressure indicators can be installed to monitor the Flo-Bar generated DP, giving a simple visual indication of flow rate. INSTALLATION INFORMATION The installation of a Flo-Bar is straightforward, but must follow the normal rules stated for Orifice Plate or similar DP devices in BS EN ISO 5167. In general this means siting the Averaging Pitot Tube at least 7 diameters downstream of a single bend, and 3 diameters upstream of a similar obstruction. On horizontal pipes, the positioning of the Pitot Tube must not allow condensation in gas flow lines, or air bubbles in liquid flows, to col lect in the head. So for gas flow measurement, for example, the Flo-Bar head must be above the pipeline, to allow any liquids to drain away. Flo Bar units can be installed in horizontal, vertical or angled pipelines: the position across the pipe diameter and the alignment of the pressure ports must be maintained within 3o for the quoted accuracy to be achieved. More information is provided in the Flo-Bar operation and maintenance manual (OMM1035), available on request. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |