| Electronic Components Datasheet Search |
|
PM101 Datasheet(PDF) 2 Page - TT Electronics. |
|
|
|||||||||||||||||||||||||||||
PM101 Datasheet(HTML) 2 Page - TT Electronics. |
|
2 / 3 page ![]() © TT Electronics plc General Note All data sheets are subject to change without notice. TT Electronics | Power Partners, Inc 43 Broad Street Suite B206, Hudson, MA 01749, USA. t: +1 (978) 567-9600 SL-xxx-xxx ISS.6 22/07/2020 Page: 2 Specifications Safety Standards & EMC Specifications EMI Standard EN55011/EN55022, FCC, and VCCI Class B (radiated and conducted) EMC Performance EN61000-3-2: Harmonic distortion, Class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±15 KV air and ± 8KV contact EN61000-4-3: Radiated immunity, 10V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 10Vrms EN61000-4-8: Magnetic field immunity, 30 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500ms, and 100% reduction for 10ms *Consult with TT Electronics for information on additional country safety approvals Input Specifications Input Voltage Range 80 to 264VAC Power derating Derate linearly from 100% at 90VAC to 90% at 85VAC and 80% at 80VAC Input Frequency Range 47 to 63Hz Input Current 2.0A (rms) for 115VAC 1.2A (rms) for 230VAC Earth Leakage Current 175μA max. @ 264VAC, 63Hz Touch Current 100μA max. @ 264 VAC, 63Hz Output Specifications Ripple & Noise 1% peak to peak maximum Overvoltage Protection Set 112-140% of nominal output voltage, latching by recycle input to reset Short circuit protection Automatic recovery Over temperature protection Latching by recycle input to reset Temperature Coefficient All outputs ±0.04%/°C maximum Transient Response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change Environmental Specifications Operating Temperature -20°C to +70°C Storage Temperature -40°C to +85°C Relative Humidity 5% to 95% non-condensing Temperature Derating De-rate from 100% at +50°C linearly to 50% at +70°C, applicable to convection and forced-air cooling conditions General Specifications Hold-up Time 10ms minimum at 80 W load and 110VAC 10ms minimum at 100W load and 115 VAC Power Factor >0.9 Switching Frequency 65 KHz (typical) Line Regulation ±0.5% maximum at full load Inrush Current 80A @ 115 Vac or 160A @ 230 Vac at 25°C cold start Withstand Voltage 4000 VAC from input to output (2 MOPP) 1500 VAC from input to ground (1 MOPP) 1500 VAC from output to ground MTBF 150,000 hours at full load at 25°C ambient, calculated per MIL- HDBK-217F |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |