| Electronic Components Datasheet Search |
|
BQ35100 Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ35100 Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 34 page ![]() 13 BQ35100 www.ti.com SLUSCM6E – JUNE 2016 – REVISED APRIL 2019 Product Folder Links: BQ35100 Submit Documentation Feedback Copyright © 2016–2019, Texas Instruments Incorporated Feature Description (continued) (1) mV when [EXTVCELL] = 0, and ADC counts when [EXTVCELL] = 1. In a SHA-1 one-way hash function, there is no known mathematical method of computing the input given, only the output. The specification of SHA-1, as defined by FIPS 180-4, states that the input consists of 512-bit blocks with a total input length less than 264 bits. Inputs that do not conform to integer multiples of 512-bit blocks are padded before any block is input to the hash function. The SHA-1 algorithm outputs the 160-bit digest. The device generates a SHA-1 input block of 288 bits (total input = 160-bit message + 128-bit key). To complete the 512-bit block size requirement of the SHA-1 function, the device pads the key and message with a 1, followed by 159 0s, followed by the 64 bit value for 288 (000...00100100000), which conforms to the pad requirements specified by FIPS 180-4. • http://www.nist.gov/itl/ • http://csrc.nist.gov/publications/fips • www.faqs.org/rfcs/rfc3174.html 7.3.8 Data Commands 7.3.8.1 Command Summary Table 1. Command Summary Table Cmd Mode Name Format Size in Bytes Min Value Max Value Default Value Unit 0x00...0x01 R/W Control Hex 2 0x00 0xff — — 0x02…0x05 R AccumulatedCapacity Integer 4 0 4.29e9 — µAh 0x06…0x07 R Temperature Signed Int 2 –32768 32767 — 0.1 K 0x08...0x09 R Voltage Integer 2 0 65535 — mV 0x0A R BatteryStatus Hex 1 0x00 0xff — — 0x0B R BatteryAlert Hex 1 0x00 0xff — — 0x0C…0x0D R Current Signed Integer 2 –32768 32767 — mA 0x16…0x17 R Scaled R Integer 2 0 65535 — mΩ 0x22…0x23 R Measured Z Integer 2 0 65535 — mΩ 0x28…0x29 R InternalTemperature Signed Integer 2 –32768 32767 — 0.1 K 0x2E…0x2F R StateOfHealth Integer 1 0 100 — % 0x3C…0x3D R DesignCapacity Integer 2 0 65535 — mAh 0x79 R Cal_Count Hex 1 0x00 0xff — 0x7a…0x7B R Cal_Current Signed Int 2 0 65535 — mA 0x7C…0x7D R Cal_Voltage Integer 2 0 65535 — mV or Counts(1) 0x7E…0x7F R Cal_Temperature Integer 2 0 65535 — K 7.3.8.2 0x00, 0x01 AltManufacturerAccess() and 0x3E, 0x3F AltManufacturerAccess() AltManufacturerAccess() provides a method of reading and writing data in the Manufacturer Access System (MAC). The MAC command is sent via AltManufacturerAccess() by a block protocol. The result is returned on AltManufacturerAccess() via a block read. Commands are set by writing to registers 0x00/0x01. On a valid word access, the MAC command state is set, and commands 0x3E and 0x3F are used for MAC commands. These new addresses work the same as 0x00 and 0x01, but are primarily intended for block writes and reads. 7.3.8.3 Control(): 0x00/0x01 Issuing a Control() command requires a subsequent two-byte subcommand. These additional bytes specify the particular control function desired. The Control() command allows the host to control specific features of the device during normal operation, and additional features when the BQ35100 device is in different access modes, as described in Table 2. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |